Results 41 to 50 of about 19,907 (261)

A Dual‐Modal Wearable PPG Smartwatch with AI‐Enhanced Correction for High‐Accuracy and Continuous AF Burden Assessment

open access: yesAdvanced Science, EarlyView.
ABSTRACT Atrial fibrillation (AF) increases the risk of stroke and heart failure, yet accurate quantification of AF burden in daily life remains difficult. Although smartwatch photoplethysmography (PPG) supports continuous monitoring, complex rhythms and signal noise can impair burden estimation.
Song Zuo   +27 more
wiley   +1 more source

Trends in Cardiac Pacemaker Batteries

open access: yesIndian Pacing and Electrophysiology Journal, 2004
Batteries used in Implantable cardiac pacemakers-present unique challenges to their developers and manufacturers in terms of high levels of safety and reliability.
Venkateswara Sarma Mallela   +2 more
doaj  

Endocardite de dispositivos, revisão com base na experiência de um centro

open access: yesRevista Portuguesa de Cardiologia, 2016
Resumo: Introdução: O número de infeções associadas com dispositivos cardíacos tem aumentado exponencialmente ao longo dos anos. Estas infeções associam‐se a elevada morbimortalidade.
Andreia Fernandes   +7 more
doaj   +1 more source

Inductive Power Transfer Link at 13.56 MHz for Leadless Cardiac Pacemakers

open access: yesEnergies, 2021
Inductive power links are most viable for the long-term powering of cardiac pacemakers. Designing an inductive power link without surpassing the specific absorption rate (SAR) for modern leadless cardiac pacemakers (LCPs) remains a challenging task ...
Krithikaa Mohanarangam   +3 more
doaj   +1 more source

A Novel Pak1 Activator Ameliorates ER Stress for HFpEF Therapy

open access: yesAdvanced Science, EarlyView.
Chronic metabolic stress is a major contributor to HFpEF progression. Under prolonged metabolic stress, Pak1 activity becomes impaired, contributing to disrupted ER proteostasis, cardiomyocyte apoptosis, fibrosis, and diastolic dysfunction. Mechanistically, Pak1 overexpression activates the ERK1/2–MNK1–eIF4E signaling axis, promotes translational ...
Honglin Xu   +17 more
wiley   +1 more source

Implantable Cardiac Pacemakers – 50 Years from the First Implantation

open access: yesZdravniški Vestnik, 2010
Background:There are over 4 million people around the world living with implanted cardiac devices. Modern pacemakers are small and light medical devices, which are implanted under local anaesthesia and provide therapy for a broad range of cardiac ...
Ratko Magjarević   +1 more
doaj  

Fully Implantable Wireless Cardiac Pacing and Sensing System Integrated with Hydrogel Electrodes

open access: yesAdvanced Science
Cardiac pacemakers play a crucial role in arrhythmia treatment. Existing devices typically rely on rigid electrode components, leading to potential issues such as heart damage and detachment during prolonged cardiac motion due to the mechanical mismatch ...
Zhiqiang Chang   +11 more
doaj   +1 more source

High‐Resolution Deep Learning Dixon Magnetic Resonance Imaging of the Sacroiliac Joints Is Noninferior to Standard Magnetic Resonance Imaging in Patients With Suspected Axial Spondyloarthritis

open access: yesArthritis &Rheumatology, EarlyView.
Objective To compare the multisequence standard magnetic resonance imaging (sMRI) protocol of the sacroiliac joints with a single high‐resolution deep learning–reconstructed Dixon sequence (DL‐Dixon) in patients with suspected axial spondyloarthritis (axSpA). Methods Seventy‐six patients with chronic low back pain and suspected axSpA underwent clinical,
Dominik Deppe   +12 more
wiley   +1 more source

External Acoustic Meatus Approach for Ultrasonographic Evaluation of the Temporomandibular Joint: An Anatomical Validation and Proof‐of‐Concept Study

open access: yesClinical Anatomy, EarlyView.
ABSTRACT Temporomandibular disorders (TMD) represent a public health problem, affecting 31% of adults and the elderly and 11% of children and adolescents. Interest is growing in using ultrasound to evaluate the temporomandibular joint (TMJ). However, researchers need to standardize a reliable method.
Rossella Alberti   +10 more
wiley   +1 more source

Incidence and Costs Related to Lead Damage Occurring Within the First Year After a Cardiac Implantable Electronic Device Replacement Procedure

open access: yesJournal of the American Heart Association: Cardiovascular and Cerebrovascular Disease, 2016
BackgroundInadvertent damage to leads for transvenous pacemakers, implantable cardioverter‐defibrillators, and cardiac resynchronization therapy defibrillators is an important complication associated with generator‐replacement procedures.
Christine I. Nichols   +2 more
doaj   +1 more source

Home - About - Disclaimer - Privacy