Results 51 to 60 of about 19,907 (261)
Same‐Day Discharge After Transcatheter Aortic Valve Implantation: Who, When, and How?
ABSTRACT The burden of severe aortic stenosis requiring treatment is growing due to ageing populations. This places increased demands on health resources due to the growing number of transcatheter aortic valve implantation (TAVI) procedures and hospital bed occupancy.
Hilal Khan +8 more
wiley +1 more source
Leadless Cardiac Pacemakers: Where are we?
The development of health technology benefits in the treatment of heart rhythm abnormalities. Cardiac pacemakers with nonsurgical methods plays a critical role in the management of patients with heart rhythms disorders.
Albert Sudharsono +2 more
doaj +1 more source
ABSTRACT Background Deflectable delivery systems have been introduced to enhance coaxial alignment and procedural efficacy during left atrial appendage occlusion (LAAO), yet randomized comparisons with conventional fixed‐curve systems are lacking. Aims The GUIDE‐LAAO trial evaluated whether the TruSteer deflectable delivery system is non‐inferior to ...
Philippe Taieb +3 more
wiley +1 more source
ABSTRACT Severe aortic stenosis (AS) carries a poor prognosis when symptomatic, particularly in cardiogenic shock (CS). Emergency transcatheter aortic valve replacement (TAVR) is rarely performed but may represent a rescue therapy. Coexistent carotid artery stenosis (CAS) further increases procedural risk.
Max Groche +3 more
wiley +1 more source
ABSTRACT Background Hypertrophic cardiomyopathy is associated with alterations in coronary microvascular function which have variable pathophysiologic mechanisms, and variable reversibility acutely and chronically following alcohol septal ablation (ASA).
Vojko V. Misevic +12 more
wiley +1 more source
Complications of Implantation of Cardiovascular Implantable Electronic Device
Introduction: Cardiovascular implantable electronic devices (CIEDs), including pacemakers, implantable cardioverter-defibrillators (ICDs), and cardiac resynchronization therapy (CRT) devices, are crucial for managing various cardiac conditions. However,
Ormir Shurdha, Endri Hasimi, Mirald Gina
doaj +1 more source
Transcatheter Tricuspid Valve Replacement for Residual Tricuspid Regurgitation After TEER
ABSTRACT Background Residual or recurrent tricuspid regurgitation (TR) after prior transcatheter tricuspid edge‐to‐edge (T‐TEER) repair occurs in about 12% of patients within 1 year. Since surgical tricuspid valve repair or replacement is of high risk, treatment options remain scarce.
Fabian Voß +14 more
wiley +1 more source
Ti3C2Tx MXene and Ag nanoparticles are embedded into piezoelectric nanofibers to form a stretchable, self‐powered coil that converts mechanical deformation into electrical energy. The device enables controllable power output during stretching and release while maintaining a compact and lightweight architecture, making it suitable for miniaturized ...
Fatemeh Mokhtari +6 more
wiley +1 more source
Cardiac magnetic resonance in a patient with MRI-conditional pacemaker
An implanted pacemaker is generally considered a contraindication for magnetic resonance imaging (MRI). The increasing number of indications for MRI and the rising prevalence of implanted cardiac pacemakers have prompted the recent development of MRI ...
António Miguel Ferreira +4 more
doaj +1 more source
Abstract Aims This study aimed to evaluate the change of the main electrocardiographic (ECG) characteristics and their prognostic role across the main subtypes of cardiac amyloidosis [light‐chain amyloidosis (AL) and hereditary (ATTRv) and wild‐type transthyretin amyloidosis (ATTRwt)].
Alessia Argirò +20 more
wiley +1 more source