Results 51 to 60 of about 76,010 (207)
Severe paravalvular leak may be observed following rapid deployment aortic valve implantation. We report an open off-label use of postdilatation ballooning of an Edwards Intuity ELITE aortic prosthesis to manage an intraoperative paravalvular ...
P. Trabattoni +3 more
core +1 more source
ABSTRACT Background Transcatheter aortic valve implantation (TAVI) with the Acurate Neo has been linked to a significant incidence of paravalvular leakage (PVL), addressed by the Acurate Neo 2 incorporating an active sealing skirt. Recent findings suggest that midframe under‐expansion is associated with worse outcomes.
Lisa Crusius +9 more
wiley +1 more source
ABSTRACT Objectives To evaluate the feasibility and short‐term outcomes of transcatheter aortic valve replacement (TAVR) using balloon‐expandable Sapien valves in patients with prior endovascular aortic stent grafts. Methods We conducted a single‐center, retrospective study of 23 patients with prior endovascular aortic stent grafts who underwent TAVR ...
Iad Alhallak +8 more
wiley +1 more source
Aims: The study aimed to compare paravalvular leak (PVL) changes after a transcatheter aortic valve replacement (TAVR) with self-expandable prosthesis between different aortic valve morphologies and evaluate the impact of paravalvular leak regression on ...
Wei Li (7081) +6 more
core +1 more source
Gutter Rotation Technique for Percutaneous Ipsilateral Retrieval of a Ruptured SAPIEN‐3 Balloon
ABSTRACT Balloon rupture during transcatheter aortic valve replacement (TAVR) with balloon‐expandable valves is a rare but potentially serious complication that may result in incomplete valve expansion, difficult device retrieval, and vascular injury.
Anne Venkata Ganeshkumar +5 more
wiley +1 more source
ABSTRACT Background Acquired aseptic intracardiac communications (AICCs) are rare but clinically relevant structural complications following transcatheter aortic valve implantation (TAVI), typically resulting from mechanical injury to the aortic annulus, interventricular septum, or adjacent structures.
Geza Fontos +6 more
wiley +1 more source
Paravalvular leak after CoreValve implantation in the Italian Registry: predictors and impact on clinical ...
Ettori F +10 more
core +1 more source
Early Experience With Evoque Transcatheter Tricuspid Valve Replacement in Carcinoid Heart Disease
ABSTRACT Tricuspid regurgitation (TR) is nearly universal in carcinoid heart disease (CHD), but surgical replacement carries significant risk, and CHD was excluded from the landmark TRISCEND II trial. We present seven patients with CHD undergoing Evoque transcatheter tricuspid valve replacement (TTVR) at two tertiary centers.
Jackson S. Burton +3 more
wiley +1 more source
Late device embolization in a persistent mitral paravalvular leak
An 83-year-old man with severe organic mitral regurgitation underwent mitral valve surgery with implantation of a biologic prosthesis. Four months later he presented with hemolytic anemia and heart failure due to severe paravalvular regurgitation.
Ana Rita Godinho +5 more
doaj +1 more source
ABSTRACT The SAPIEN M3 system has been recently approved for transcatheter mitral valve replacement (TMVR). The transeptal guide sheath is used to deploy the dock, which is completely released before inserting and deploying the M3 valve using the same femoral access, transeptal puncture (TSP) and guide sheath.
Clara Fernandez‐Cordon +5 more
wiley +1 more source

