Results 71 to 80 of about 76,010 (207)

Principles of Percutaneous Paravalvular Leak Closure

open access: yesJACC: Cardiovascular Interventions, 2012
Paravalvular regurgitation affects 5% to 17% of all surgically implanted prosthetic heart valves. Patients who have paravalvular regurgitation can be asymptomatic or present with hemolysis or heart failure, or both. Reoperation is associated with increased morbidity and is not always successful because of underlying tissue friability, inflammation, or ...
Rihal, Charanjit S.   +4 more
openaire   +2 more sources

Comparable Outcomes of Bicuspid Aortic Valves for Rapid- Deployment Aortic Valve Replacement

open access: yesJournal of Chest Surgery, 2023
Background: Edwards Intuity is recognized as a relatively contraindicated bioprosthesis for bicuspid aortic valve disease. This study compared the early echocardiographic and clinical outcomes of rapid-deployment aortic valve replacement for bicuspid ...
Somin Im   +5 more
doaj   +1 more source

Culture‐Negative Infective Endocarditis Presumed due to Brucella Causing Rapid Native Aortic Valve Destruction in a Young Adult: A Case Report

open access: yesClinical Case Reports, Volume 14, Issue 10, October 2026.
ABSTRACT Culture‐negative endocarditis with features consistent with Brucella can rapidly destroy a normal aortic valve in young adults. 2023 Duke‐ISCVID criteria (clinical/imaging findings plus histopathology), supported by serology and occupational exposure enabled urgent combined antimicrobial‐surgical management without culture confirmation ...
Baraa Nassar   +5 more
wiley   +1 more source

Repair of mitral paravalvular leak with double left atrial wall folding

open access: yes, 2013
Mitral paravalvular leaks can be repaired by alternative repair techniques instead of direct suture repair of the leak site. We report our technique of double left atrial wall folding for repair of posterior mitral paravalvular leaks. © 2013 The Japanese
Lafci, Gokhan   +5 more
core   +1 more source

Early Multicenter Outcomes of Dedicated Transcatheter Aortic Valve Replacement for Left Ventricular Assist Device‐Associated Pure Aortic Regurgitation

open access: yesArtificial Organs, Volume 50, Issue 10, Page 1427-1433, October 2026.
LVAD‐associated aortic regurgitation impairs circulatory support, with limited surgical and off‐label options. In a multicenter registry (n = 30), the AR‐dedicated JenaValve Trilogy TAVR eliminated AR, achieving 96.7% (29/30) technical success and 93.3% (28/30) device success (VARC‐3), with 3.3% (1/30) 30‐day mortality.
Hristian Hinkov   +13 more
wiley   +1 more source

Paravalvular leak after mechanical aortic valve replacement causing hemolytic anemia: Closure with vascular plug

open access: yes, 2016
We report a case of a 79-year-old man with hemolytic anemia caused by a small paravalvular leak after aortic valve replacement with mechanical prosthesis.
Watson, T.   +4 more
core   +1 more source

Same‐Day Discharge After Transcatheter Aortic Valve Implantation: Who, When, and How?

open access: yesCatheterization and Cardiovascular Interventions, Volume 108, Issue 3, Page 816-823, September 1, 2026.
ABSTRACT The burden of severe aortic stenosis requiring treatment is growing due to ageing populations. This places increased demands on health resources due to the growing number of transcatheter aortic valve implantation (TAVI) procedures and hospital bed occupancy.
Hilal Khan   +8 more
wiley   +1 more source

Percutaneous closure of paravalvular leak after Cone repair for Ebstein's anomaly

open access: yes, 2019
We report the use of an Amplatzer Vascular plug for percutaneous closure of a paravalvular leak after Cone repair in a 5-year-old boy with Ebstein's anomaly. A paravalvular leak of the tricuspid valve developed gradually after Cone repair-surgery.
Alderweireldt, Ann-Sofie   +2 more
core   +1 more source

Effectiveness of an Information Platform‐Based Multidisciplinary Enhanced Recovery After Surgery Program on Recovery After Transcatheter Aortic Valve Implantation: A Non‐Concurrent Controlled Study

open access: yesNursing Open, Volume 13, Issue 9, September 2026.
ABSTRACT Aim To evaluate the implementation effectiveness of a multicomponent multidisciplinary Enhanced Recovery After Surgery pathway integrated with an information platform for patients undergoing transcatheter aortic valve implantation. Design A single‐center quasi‐experimental study with a non‐concurrent historical control group.
Shaoping Lin   +6 more
wiley   +1 more source

Clinical and Echocardiographic Outcomes After Implantation of the ALLEGRA Transcatheter Valve Using the Fully Repositionable IMPERIA Delivery System: One‐Year Results of the EMPIRE I Study

open access: yesCatheterization and Cardiovascular Interventions, Volume 108, Issue 2, Page 540-547, August 1, 2026.
ABSTRACT Background The EMPIRE I study assessed the early (30 days) safety and efficacy of a new fully repositionable delivery system (IMPERIA) for the commercially available ALLEGRA transcatheter aortic valve in patients with either severe native aortic stenosis or a degenerated surgical bioprosthesis.
José Antonio Baz   +15 more
wiley   +1 more source

Home - About - Disclaimer - Privacy