Results 91 to 100 of about 18,769 (219)
Massive Silicone Oil Migration into the Subconjunctival Space: A Leakage Mechanism Dilemma
Purpose: To report a case in which an early, massive silicone oil migration into the subconjunctival space occurred in a patient after sutureless vitrectomy with the presence of a previously implanted pars plana glaucoma drainage device.
Jesús Téllez +3 more
doaj +1 more source
Purpose Comparing between the visual outcomes and post operative complications of two surgical treatments for sub macular hemorrhage, pars plana vitrectomy with tissue plasminogen activator (tPA) injection procedure, and pneumatic displacement of ...
Aya Barzelay +5 more
doaj +1 more source
Yukari Shirakata,1 Kouki Fukuda,1 Tomoyoshi Fujita,1 Yuki Nakano,1 Hiroyuki Nomoto,2 Hidetaka Yamaji,3 Fumio Shiraga,4 Akitaka Tsujikawa1 1Department of Ophthalmology, Faculty of Medicine, Kagawa University, Miki-cho, 2Nomoto Eye Clinic, Himeji ...
Fukuda K +7 more
core
Lamellar macular hole formation following vitrectomy for rhegmatogenous retinal detachment repair
Tina Xirou, Andrej Kidess, Christina Kourentis, Vasiliki Xirou, Elias Feretis, Stamatina A KabanarouRetina Department, Hellenic Red Cross General Hospital, Athens, GreeceBackground: The purpose of this study was to investigate lamellar macular hole ...
Kabanarou SA +5 more
doaj
Pars plana vitrectomy for retinal detachment with unseen retinal holes
A study was made of a consecutive series of 47 cases of rhegmatogenous retinal detachment treated by pars plana vitrectomy in which no holes were identified preoperatively.
Chignell, AH, Wong, D, Billington, BM
core +1 more source
Background Posterior synechiae of the iris rarely cause secondary angle-closure glaucoma after pars plana vitrectomy, mainly reported in cases with high postoperative inflammation.
Shigefumi Takahashi +2 more
doaj +1 more source
Introduction: Silicone oil is a widely used intraocular tamponade in complex retinal detachment surgery. However, its use may lead to secondary glaucoma, with reported incidence ranging from 5% to 56%.
Rafał Woś +2 more
core +1 more source
Acrylic intraocular lens placement in conjunction with pars plana vitrectomy
PURPOSE: To report the results of placing a foldable acrylic intraocular lens through a clear cornea incision in eyes undergoing pars plana vitrectomy.
Smiddy, William E +5 more
core +1 more source
Qiong Huang, Yang Cheng Department of Ophthalmology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, 430022, People’s Republic of ChinaCorrespondence: Yang ChengDepartment of Ophthalmology, Union
Huang Q, Cheng Y
doaj