Partially coherent nano-focused x-ray radiation characterized by Talbot interferometry
We have studied the spatial coherence properties of a nano-focused x-ray beam by grating (Talbot) interferometry in projection geometry. The beam is focused by a fixed curvature mirror system optimized for high flux density under conditions of partial coherence.
Salditt, Tim +7 more
openaire +5 more sources
Comparative Analysis of Axial Length Measurements by Optical Biometers Based on Partial Coherence Interferometry Versus Optical Low-Coherence Interferometry: An Office Audit. [PDF]
Bhullar H +3 more
europepmc +3 more sources
Partial coherence interferometry versus immersion ultrasonography for axial length measurement in children. [PDF]
Lenhart PD +3 more
europepmc +3 more sources
Purpose: To compare axial length (AL) measurements between a swept-source optical coherence tomography (SS-OCT) biometer (IOLMaster 700) and a partial coherence interferometry (PCI) biometer (IOLMaster, version 5.4) in myopic eyes.
Jong Yun Yang +2 more
openalex +3 more sources
PURPOSE: To compare the postoperative refractive error (RE) using A-scan ultrasound (US) and partial coherence interferometry (PCI) after phacovitrectomy for idiopathic epiretinal membrane (iERM) and cataract. METHODS: Eighty-eight participants (88 eyes)
Eui Chun Kang +2 more
openalex +3 more sources
Purpose Precise ocular measurements are fundamental for achieving excellent target refraction following both cataract surgery and refractive lens exchange. Biometry devices with swept-source optical coherence tomography (SS-OCT) employ longer wavelengths
Piotr Kanclerz +2 more
doaj +1 more source
Analysis of keratometric measurements in accordance with axial length in an aged population
To investigate keratometric measurements according to axial length in an aged population. Patients requiring cataract surgery with keratometric measurements from four different ophthalmic devices (autorefractor/keratometer, Scheimpflug imaging, corneal ...
Sung Uk Han +7 more
doaj +1 more source
Comparison of two optical biometers in intraocular lens power calculation
Aims: To compare the consistency and accuracy in ocular biometric measurements and intraocular lens (IOL) power calculations using the new optical low-coherence reflectometry and partial coherence interferometry.
Sheng Hui, Lu Yi
doaj +1 more source
OBJECTIVE: To analyze refractive results in postoperative cataract surgery in eyes previously submitted to keratotomy using Haigis formula and data provided by IOL Master®optical biometer.
Juan Carlos Sánchez Caballero +1 more
doaj +1 more source