Results 11 to 20 of about 2,558,440 (284)
Intermittent partial discharge has become an essential threat to the safety and stability of high voltage electrical equipment. In order to reduce the sudden insulation breakdown failure due to the intermittent and latent partial discharge of the ...
Bo Niu, Dr +5 more
doaj +3 more sources
Double-End Location Technology of Partial Discharge in Cables Based on Frequency-Domain Reflectometry [PDF]
To realize the region determination and accurate location of cable partial discharge, this paper proposes a cable partial discharge double-end location technique based on frequency-domain reflectometry.
Wang Miao +9 more
doaj +2 more sources
Domain-Adaptive Transformer Partial Discharge Recognition Method Combining AlexNet-KAN with DANN [PDF]
The changes in operating conditions of a power transformer can cause a shift in the distribution of partial discharge data, leading to the gradual generation of unlabeled new data, which results in the degradation of the original partial discharge ...
Jianfeng Niu, Yongli Zhu
doaj +2 more sources
Interpretation of partial discharge activity in the presence of harmonics [PDF]
Recent work has identified that circumstances of equipment operation can radically change condition monitoring data. This contribution investigates the significance of considering circumstance monitoring on the diagnostic interpretation of such condition
Rowland, S.M. +4 more
core +4 more sources
Modeling partial discharge phenomena [PDF]
Measurements of partial discharge (PD) activity are a commonly used technique to diagnose the health of insulation material within high voltage plant. The definition of PD is relatively broad, it is generally defined as a localized or confined discharge within an insulating medium [1]. Due to the high electric breakdown strength of insulation materials,
Callender, George, Lewin, Paul
openaire +1 more source
Partial discharge inception modeling is a powerful tool for material investigation and insulation system design in order to achieve the objective of PD-free operation of insulation systems.
Giovanni Gardan, Gian Carlo Montanari
doaj +1 more source
Partial discharge Source Calibration of Radiated Partial Discharge Signals
Based on the IEC 60270 guideline, a galvanic quantification along with free-space radiometry (FSR) method are used to measure partial discharge (PD) simultaneously. The PD source is a floating-electrode emulator type that was custom built. Sources are powered by AC or DC, power supplies. A biconical antenna captures the emitted a signal.
Jaber, Adel +2 more
openaire +1 more source
Simulation Analysis on Partial Discharge Signals Produced by Multiple Insulation Defects in GIS [PDF]
In this paper, the simulation analysis on partial discharge (PD) signals produced by multiple insulation defects in gas insulated substation (GIS) has been researched by the simulation software of electromagnetic field (XFDTD).
Yun Yuxin +4 more
doaj +1 more source
Identifying harmonic attributes from online partial discharge data [PDF]
Partial discharge (PD) monitoring is a key method of tracking fault progression and degradation of insulation systems. Recent research discovered that the harmonic regime experienced by the plant also affects the PD pattern, questioning the conclusions ...
Rowland, S.M. +4 more
core +4 more sources
A frequency-based RF partial discharge detector for low-power wireless sensing [PDF]
Partial discharge (PD) monitoring has been the subject of significant research in recent years, which has given rise to a range of well-established PD detection and measurement techniques, such as acoustic and RF, on which condition monitoring systems ...
Baker, P.C. +2 more
core +4 more sources

