Results 31 to 40 of about 608,168 (303)
Interpretation of partial discharge activity in the presence of harmonics [PDF]
Recent work has identified that circumstances of equipment operation can radically change condition monitoring data. This contribution investigates the significance of considering circumstance monitoring on the diagnostic interpretation of such condition
Bahadoorsingh, S. +4 more
core +1 more source
A GIS Partial Discharge Defect Identification Method Based on YOLOv5
The correct identification of partial discharge types is of great significance to the stable operation of GIS. In order to improve the recognition accuracy and result of partial discharge, and to meet the requirements of real-time monitoring of GIS ...
Yao Lu +5 more
doaj +1 more source
Characteristics of PD for Dry-type Air-core Reactor in Turn-to-turn Insulation under Step-voltage
Turntoturn insulation breakdown is the final expression form of turntoturn insulation fault for the drytype aircore reactor, the partial discharge under over voltage is one of the main factors causing the turntoturn insulation damage. In order to
YAO Yuan-hang +4 more
doaj +1 more source
Partial discharge in liquid nitrogen
Results are presented of experiments on partial discharge in liquid nitrogen, including insulation breakdown characteristics of liquid nitrogen, partial discharge characteristics of composite insulation systems, lifetime of polymer films, impulse breakdown of polymer films in liquid nitrogen, etc.
Masamitsu Kosaki +3 more
openaire +2 more sources
Current Density Distribution in the Metal Enclosure of GIS in the Presence of Partial Discharges [PDF]
Reliable operation of GIS is an important guarantee for the safety and stability of the power system. Partial discharge detection is an effective means of detecting GIS faults in the partial discharge. When partial discharge occurs, the partial discharge
Xu Dai, Changyong Yin, Guanhua Li
doaj +1 more source
In this paper, the different types of discharge in transformer were simulated based on the real transformer fault model. The optical partial discharge detection system was established based on optical sensors which were capturing partial discharge ...
Wei Bengang +3 more
doaj +1 more source
Robust on-line partial discharge measurement of 35-kV cables in wind farms via dual sensors
Condition-based maintenance of cables in wind farms is critical for their operation reliability and stability. A promising solution to this task is to carry out on-line partial discharge measurement on the cables.
Yuan Yan, Peng Huo, Hongjie Li
doaj +1 more source
Development of an integrated low-power RF partial discharge detector [PDF]
This paper presents the results from integrating a low-power partial discharge detector with a wireless sensor node designed for operating as part of an IEEE 802.15.4 sensor network, and applying an on-line classifier capable of classifying partial ...
Baker, P.C. +3 more
core +1 more source
Partial discharge pattern recognition method for mine-used dry-type transformer
In order to improve recognition accuracy of partial discharge pattern of mine-used dry-type transformer, a partial discharge pattern recognition method for mine-used dry-type transformer was proposed.
TANG Jianwei +5 more
doaj +1 more source
A novel image‐orientation feature extraction method for partial discharges
Partial discharge identification is of great significance in monitoring power equipment. Although substantial work has been done in partial discharge pattern recognition, most studies have been performed in noise‐free environments.
Ze Li +5 more
doaj +1 more source

