Results 11 to 20 of about 42,017 (255)
To improve the safety and antielectromagnetic interference performance of partial discharge detection in high-voltage DC cables, partial discharge of cables is used as a criterion for characterizing insulation defects.
Zhiheng Liu +4 more
doaj +1 more source
In order to effectively detect latent insulation faults at oil-filled cable terminals, the finite element analysis method of acoustic field is used to study the characteristics of partial discharge acoustic field distribution at oil-filled cable ...
DU Liang +5 more
doaj +1 more source
Detection technology of partial discharge in transformer based on optical signal
The detection of partial discharge (PD) in transformers is of great significance for preventing insulation defects from developing into insulation failures. Transformer partial discharge detection technology includes pulse current method, radio frequency
Shuangrui Jia +5 more
doaj +1 more source
Optical fiber sensors are used for partial discharge detection in many applications due their advantage of strong anti-electromagnetic interference capability.
Zhengxian Zhou +6 more
doaj +1 more source
The paper introduced basic principle, detection and determinants of partial discharge detection method based on a combination method of ultrasound and high-frequency current.
LUO Dongsong, LU Ye
doaj +1 more source
Denoising Analysis of Partial Discharge Acoustic Signal Based on SVMD-PCA
Partial discharge (PD) acoustic signal detection is one of the effective means to assess the insulation status of power transformers. In actual monitoring, white noise is likely to cause strong interference to the partial discharge acoustic signal of the
Panpan Cao +3 more
doaj +1 more source
Current Density Distribution in the Metal Enclosure of GIS in the Presence of Partial Discharges [PDF]
Reliable operation of GIS is an important guarantee for the safety and stability of the power system. Partial discharge detection is an effective means of detecting GIS faults in the partial discharge. When partial discharge occurs, the partial discharge
Xu Dai, Changyong Yin, Guanhua Li
doaj +1 more source
Device for online monitoring of insulation faults in high-voltage switchgears
Partial discharges are the major cause of deterioration in the insulation characteristics of switchgears. Therefore, timely detection of partial discharge in switchgear and potential insulation faults is an urgent problem that needs to be addressed in ...
Jiajia Song, Jinbo Zhang, Xinnan Fan
doaj +1 more source
Partial discharge signals are prone to missed detection under low signal-to-noise ratios, and the traditional singular value decomposition algorithm requires massive calculations when extracting partial discharge pulses.
Li WANG, Wei ZHANG, Dingnan LUO
doaj +1 more source
In the authors’ previous research, a new method for partial discharge detection in the switchgear based on near-field detection was proposed. The content of this paper is the continuation of the authors’ previous research.
Chunguang Suo +6 more
doaj +1 more source

