Results 1 to 10 of about 11,814 (147)
Design and Evaluation of a Flexible Substrate-Based Microstrip Sensor for Partial Discharge Detection in High-Voltage Equipment [PDF]
Partial discharge (PD) detection effectively identifies insulation defects in power equipment. Radio frequency (RF) methods for PD detection offer promising advantages due to their non-invasive measurement capability and ability to locate discharge ...
Shuhao Dong, Xiao Hu
doaj +2 more sources
Analysis of Charge Parameter Characteristics of Graphene Partial Discharge Sensor Based on First-Principles Study [PDF]
With the proposal of transparent power grids, advanced sensor research has become a hot topic. A partial discharge (PD) sensor is a specialized device that captures electrical signals generated by partial discharge phenomena in power system insulation ...
Huiyuan Zhang +4 more
doaj +2 more sources
An Evaluation Method for Partial Discharge in Generator Stator Bar Insulation Based on Fiber-Optic Acoustic Detection [PDF]
Partial-discharge (PD) monitoring is essential for assessing the insulation condition of generator stator bars. Conventional methods are susceptible to electromagnetic interference and are difficult to deploy in confined stator geometries.
Jianlin Hu +4 more
doaj +2 more sources
Overview and Partial Discharge Analysis of Power Transformers: A Literature Review
The high voltage power transformer is the critical element of the power system, which requires continuous monitoring to prevent sudden catastrophic failures and to ensure an uninterrupted power supply.
Md Rashid Hussain +2 more
doaj +1 more source
In-depth exploration of partial discharge modelling methods within insulations
Partial discharge (PD) activities are the essential contributor of insulation failure, which constitute more than 60% for damaging high voltage equipment.
Hadi Nabipour Afrouzi +6 more
doaj +1 more source
The suitability of corn oil nanofluid as an insulation material is studied herein by analysing the partial discharge characteristics. Experiments are conducted on nano‐silica modified corn oil at 0.01, 0.05, and 0.1 wt.% mass fractions.
Shantha Kumar M +2 more
doaj +1 more source
Partial discharge inception modeling is a powerful tool for material investigation and insulation system design in order to achieve the objective of PD-free operation of insulation systems.
Giovanni Gardan, Gian Carlo Montanari
doaj +1 more source
Simulation Analysis on Partial Discharge Signals Produced by Multiple Insulation Defects in GIS [PDF]
In this paper, the simulation analysis on partial discharge (PD) signals produced by multiple insulation defects in gas insulated substation (GIS) has been researched by the simulation software of electromagnetic field (XFDTD).
Yun Yuxin +4 more
doaj +1 more source
Partial discharge is one of the main reasons for insulation degradation in high‐voltage apparatuses. Partial discharge is an ineluctable phenomenon that happens when a high electrical field is adjacent to an insulator. High‐frequency current transformers
Hamidreza Besharatifard +3 more
doaj +1 more source
Partial Discharge Analysis and Simulation Using the Consecutive Pulses Correlation Method
The behaviour of partial discharge as consequences of an alternating current (AC) is already well defined. AC partial discharges have completely different behaviour, background physics and parameters than partial discharges (PD) under direct current (DC)
Ondřej Kozák, Josef Pihera
doaj +1 more source

