Results 21 to 30 of about 86,487 (250)
Low-Cost Online Partial Discharge Monitoring System for Power Transformers
The article presents in detail the construction of a low-cost, portable online PD monitoring system based on the acoustic emission (AE) technique.
W. Sikorski, Artur Wielewski
semanticscholar +1 more source
Measurement of Partial Discharge Activities within Two Artificial Spherical Voids in an Epoxy Resin [PDF]
Measurement of partial discharge activities within insulation systems has been extensively performed. It has been widely used in the performance assessment of an insulation system and for insulation diagnostics.
Illias, H A +5 more
core +1 more source
This paper deals with a time-frequency analysis of the measured partial discharge (PD) currents in different insulation gases. These gas environments consist of a pure SF6 (sulphur-hexafluoride) and sulphur-hexafluoride and nitrogen (1 % SF6 + 99 % N2 ...
Arikan Kemal, Önal Emel, Şeker Serhat
doaj +1 more source
Partial Discharge Behaviour within Two Spherical Cavities in a Dielectric Material [PDF]
In high voltage insulation systems, a typical defect that exists is a void cavity. It is known that voids are a common source of partial discharge (PD) activity within an insulation system.
Illias, H A +5 more
core +1 more source
In this paper, the practical application of a bio-inspired antenna for partial discharge (PD) detection in high voltage equipment was evaluated in order to validate the efficiency of using this technology for PD monitoring purposes.
Josiel Cruz +7 more
doaj +1 more source
Partial discharges characteristics study in XLPE cable insulation with multiple defects [PDF]
The paper simulates the electric field intensity picture in the cable with one and several defects. Modeling has shown that the presence of several closely spaced defects does not lead to an increase in the electric field intensity in comparison with
I. V. Komarov +2 more
doaj +1 more source
Partial discharge. Part XXIV: The analysis of PD in HVDC equipment
High voltage dc is required in a wide range of consumer, commercial, and military applications. Presently available PD analysis for dc systems can extend far beyond the old-fashioned "not more than 'n' PD pulses per minute over a given magnitude".
Morshuis, P. (author) +2 more
openaire +3 more sources
SF6 Decomposed Component Analysis for Partial Discharge Diagnosis in GIS: A Review
This paper compiles, summarizes, and deliberates over one hundred important works on the different approaches and advances in the surveillance and diagnosis of the internal status of SF6 gas-insulated equipment (GIE), particularly partial discharge (PD ...
Ammar Salah Mahdi +2 more
semanticscholar +1 more source
To investigate partial discharge‐induced deterioration characteristics of ethylene‐propylene rubber (EPR) cable insulation under repeated alternating current (AC) voltage on high‐speed trains, an experimental platform with a column‐plate EPR insulation ...
Longlei Bai +6 more
doaj +1 more source
Partial discharge (PD) is a major cause of degradation of motor winding insulation. It is a challenge to the successful electrification of all types of ground, sea, and aerial vehicles.
Zhuo Wei +4 more
semanticscholar +1 more source