Results 21 to 30 of about 2,966,124 (288)
Measurement of Partial Discharge Activities within Two Artificial Spherical Voids in an Epoxy Resin [PDF]
Measurement of partial discharge activities within insulation systems has been extensively performed. It has been widely used in the performance assessment of an insulation system and for insulation diagnostics.
Illias, H A, Lewin, P L, Chen, G
core +2 more sources
In this paper, the practical application of a bio-inspired antenna for partial discharge (PD) detection in high voltage equipment was evaluated in order to validate the efficiency of using this technology for PD monitoring purposes.
Josiel Cruz +7 more
doaj +1 more source
Partial discharge. Part XXIV: The analysis of PD in HVDC equipment
High voltage dc is required in a wide range of consumer, commercial, and military applications. Presently available PD analysis for dc systems can extend far beyond the old-fashioned "not more than 'n' PD pulses per minute over a given magnitude".
Morshuis, P. (author) +2 more
openaire +3 more sources
Partial discharges characteristics study in XLPE cable insulation with multiple defects [PDF]
The paper simulates the electric field intensity picture in the cable with one and several defects. Modeling has shown that the presence of several closely spaced defects does not lead to an increase in the electric field intensity in comparison with
I. V. Komarov +2 more
doaj +1 more source
Partial Discharge Behaviour within Two Spherical Cavities in a Dielectric Material [PDF]
In high voltage insulation systems, a typical defect that exists is a void cavity. It is known that voids are a common source of partial discharge (PD) activity within an insulation system.
Illias, H A, Lewin, P L, Chen, G
core +2 more sources
To investigate partial discharge‐induced deterioration characteristics of ethylene‐propylene rubber (EPR) cable insulation under repeated alternating current (AC) voltage on high‐speed trains, an experimental platform with a column‐plate EPR insulation ...
Longlei Bai +6 more
doaj +1 more source
Multiple detections of insulation defects partial discharge in gas-insulated equipment
Gas-insulated equipment is an important part of the power system owing to its advantages of small footprint, large transmission capacity, and high reliability.
Fanjun Kong +7 more
doaj +1 more source
Partial Discharge Analysis in High-Frequency Transformer Based on High-Frequency Current Transducer
High-frequency transformers are the core components of power electronic transformers (PET), whose insulation is deeply threatened by high voltage (HV) and high frequency (HF). The partial discharge (PD) test is an effective method to assess an electrical
Jun Jiang +5 more
doaj +1 more source
Partial discharge on-line monitoring for HV cable systems using electro-optic modulators [PDF]
A technique for the remote inspection and monitoring of partial discharge (PD) activity using an optical network is described. The network uses a LiNbO3 modulator to modulate the intensity of the transmitted laser light approximately proportional to the ...
Pommerenke, David +9 more
core +1 more source
Temperature has an important influence on the partial discharge (PD) development, but the effect of temperature on the PD initiation mechanism is still not fully understood.
Weiwei LI +5 more
doaj +1 more source