Results 21 to 30 of about 80,385 (313)
To investigate partial discharge‐induced deterioration characteristics of ethylene‐propylene rubber (EPR) cable insulation under repeated alternating current (AC) voltage on high‐speed trains, an experimental platform with a column‐plate EPR insulation ...
Longlei Bai +6 more
doaj +1 more source
A frequency-based RF partial discharge detector for low-power wireless sensing [PDF]
Partial discharge (PD) monitoring has been the subject of significant research in recent years, which has given rise to a range of well-established PD detection and measurement techniques, such as acoustic and RF, on which condition monitoring systems ...
Baker, P.C. +2 more
core +1 more source
Diagnostic Potential of Free-Space Radiometric Partial Discharge Measurements [PDF]
The work reported in this paper addresses the calibration of four types of partial discharge (PD) emulator required for the development of a PD Wireless Sensor Network (WSN).
Atkinson, R. +9 more
core +1 more source
Radiometric Wireless Sensor Network Monitoring of Partial Discharge Sources in Electrical Substations [PDF]
A wireless sensor network (WSN) with the potential to monitor and locate partial discharge (PD) in high-voltage electricity substations using only received signal strength (RSS) is proposed.
Ahmed, Hamd +12 more
core +2 more sources
Temperature has an important influence on the partial discharge (PD) development, but the effect of temperature on the PD initiation mechanism is still not fully understood.
Weiwei LI +5 more
doaj +1 more source
Partial Discharge Analysis in High-Frequency Transformer Based on High-Frequency Current Transducer
High-frequency transformers are the core components of power electronic transformers (PET), whose insulation is deeply threatened by high voltage (HV) and high frequency (HF). The partial discharge (PD) test is an effective method to assess an electrical
Jun Jiang +5 more
doaj +1 more source
This paper investigates partial discharge (PD) characteristics that lead to the erosion of silicone rubber (SR) polymer under AC stress and DC stress of both polarities.
Valeria Pevtsov +2 more
doaj +1 more source
Analysis of Cavity PD Characteristics’ Sensitivity to Changes in the Supply Voltage Frequency
The supply voltage frequency effect on partial discharge (PD) phenomena has continued to draw research interest. Although most high voltage equipment operates at power frequency (50/60 Hz), testing is often done at different frequencies for various ...
Tapiwa Venge, Cuthbert Nyamupangedengu
doaj +1 more source
The partial discharge (PD) is the most common fault of transformers, which is the main factor affecting the stable operation of transformers. Therefore, the PD should be monitored and identified timely to improve the reliability of the transformers.
Shengya Sun +5 more
doaj +1 more source
Effects of shorter phase-resolved partial discharge duration on PD classification accuracy
<span>Partial discharge (PD) pattern recognition is useful to diagnose insulation condition. PD measurement data is commonly represented in phase-resolved partial discharge (PRPD) format. PRPD is useful as it provides a visible pattern for different PD source and various features can be extracted for PD pattern recognition.
Xin, Chong Wan +4 more
openaire +3 more sources

