Results 31 to 40 of about 86,487 (250)
Multiple detections of insulation defects partial discharge in gas-insulated equipment
Gas-insulated equipment is an important part of the power system owing to its advantages of small footprint, large transmission capacity, and high reliability.
Fanjun Kong +7 more
doaj +1 more source
Optimized Denoising Method for Weak Acoustic Emission Signal in Partial Discharge Detection
Acoustic emission (AE) technology can predict the occurrence of partial discharge (PD) faults, which is used to improve the safe operation level of gas-insulated switchgear (GIS) equipment.
Qingcheng Lin +4 more
semanticscholar +1 more source
Medium-frequency (MF) transformer in a phase-shift modulated dc solid state transformer (SST) is prone to partial discharge (PD) that impacts the system reliability and lifetime.
R. Agarwal +3 more
semanticscholar +1 more source
Partial Discharge Analysis in High-Frequency Transformer Based on High-Frequency Current Transducer
High-frequency transformers are the core components of power electronic transformers (PET), whose insulation is deeply threatened by high voltage (HV) and high frequency (HF). The partial discharge (PD) test is an effective method to assess an electrical
Jun Jiang +5 more
doaj +1 more source
This paper investigates partial discharge (PD) characteristics that lead to the erosion of silicone rubber (SR) polymer under AC stress and DC stress of both polarities.
Valeria Pevtsov +2 more
doaj +1 more source
Analysis of Cavity PD Characteristics’ Sensitivity to Changes in the Supply Voltage Frequency
The supply voltage frequency effect on partial discharge (PD) phenomena has continued to draw research interest. Although most high voltage equipment operates at power frequency (50/60 Hz), testing is often done at different frequencies for various ...
Tapiwa Venge, Cuthbert Nyamupangedengu
doaj +1 more source
Intelligent partial discharge sensing system for power grid equipment based on Internet of things
Aiming at the problem that the traditional manual inspection method and wired communication method are difficult to meet the demand for partial discharge (PD) detection of large-scale power equipment, this paper designs an intelligent partial discharge ...
FANG Zheng
doaj +1 more source
Temperature has an important influence on the partial discharge (PD) development, but the effect of temperature on the PD initiation mechanism is still not fully understood.
Weiwei LI +5 more
doaj +1 more source
The partial discharge (PD) is the most common fault of transformers, which is the main factor affecting the stable operation of transformers. Therefore, the PD should be monitored and identified timely to improve the reliability of the transformers.
Shengya Sun +5 more
doaj +1 more source
A frequency-based RF partial discharge detector for low-power wireless sensing
Partial discharge (PD) monitoring has been the subject of significant research in recent years, which has given rise to a range of well-established PD detection and measurement techniques, such as acoustic and RF, on which condition monitoring systems ...
Baker, P.C. +2 more
core +1 more source