Results 41 to 50 of about 86,487 (250)
Partial discharge on-line monitoring for HV cable systems using electro-optic modulators
A technique for the remote inspection and monitoring of partial discharge (PD) activity using an optical network is described. The network uses a LiNbO3 modulator to modulate the intensity of the transmitted laser light approximately proportional to the ...
Pommerenke, David +9 more
core +1 more source
Effect of SF6 pressure on the sensitivity of partial discharge detection of typical defects in GIS
The gas pressure of gas insulated switchgear (GIS) is the key factor affecting the sensitivity of partial discharge (PD) detection. In this paper, four defect models, tip, suspension, void, surface, are constructed on the PD experimental platform.
KONG Fanjun +3 more
doaj +1 more source
Partial discharge (PD) detection of cable terminals is crucial for the safe operation of the traction power system in trains. However, similar PD signals in complex train‐operating environments cause difficulty to recognise the insulation defects ...
Kai Liu +8 more
semanticscholar +1 more source
Scientific evaluation of partial discharge (PD) severity in gas-insulation switchgear (GIS) can assist in mastering the insulation condition of in-service GIS.
Ju Tang +6 more
doaj +1 more source
Power transformers are considered important and expensive items in electrical power networks. In this regard, the early discovery of potential faults in transformers considering datasets collected from diverse sensors can guarantee the continuous ...
S. Ward +6 more
semanticscholar +1 more source
Gas insulated switchgear (GIS) in service may tolerate large temperature changes, which leads to uncertainty in the evaluation of the partial discharge (PD) signal.
Hui Song +4 more
semanticscholar +1 more source
Partial discharge (PD) is an electrical discharge within a dielectric which does not bridge the electrodes. PD measurement has been widely used for assessing performance of insulation systems.
P L Lewin +5 more
core +1 more source
A wireless sensor network (WSN) with the potential to monitor and locate partial discharge (PD) in high-voltage electricity substations using only received signal strength (RSS) is proposed.
Jaber, Adel +27 more
core +1 more source
Oil–paper insulation in oil-immersed transformers undergoes a concealed degradation process that is difficult to detect during operation. To understand its discharge behavior, this study examines partial discharge characteristics under controlled ...
Ruiming Wang +4 more
doaj +1 more source
Analysis of partial discharge Ultrasonic wave characteristic on typical Defects in GIS
For analyzing partial discharge ultrasonic wave characteristic on typical defects in SF6 gas insulation switchgear (GIS), a 110 kV GIS was taken as an object to design and simulate the typical partial discharge models in GIS.
Yang Jing Gang +4 more
doaj +1 more source

