Results 231 to 240 of about 5,169,554 (284)
Some of the next articles are maybe not open access.

Measuring the endurance of films in partial discharges

IEEE Transactions on Electrical Insulation, 1993
A new test assembly for measuring the endurance of polymeric and ceramic films under the action of partial discharges (PDs) is presented. If experiments are performed under controlled ambient conditions (i.e., relative humidity), the test procedure gives times to breakdown which show low scatter. The effects of different test conditions on the times to
R. Bozzo   +2 more
openaire   +2 more sources

On line measurement of partial discharges

2000 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.00CH37132), 2002
On line measurement of partial discharges of equipment while in service has a great deal of potential in saving equipment down time in gas insulated substations (GIS) and gas insulated transmission lines (GITL). To address this aspect of partial discharge measurement there is scope for considerable progress particularly in the area of cables already is
N. Srinivas, N. Ahmed, G. Raju
openaire   +1 more source

Partial Discharge Measurement

2014
This chapter is devoted to the measurement of partial discharges (PD) localized in weak spots of dielectrics if subjected to high test voltages. As standards for PD measurement s have been introduced only for quality assurance tests of HV apparatus energized by power frequency AC voltages (50/60 Hz), the following treatment refers mainly to this test ...
Wolfgang Hauschild, Eberhard Lemke
openaire   +1 more source

Innovative Solutions for Partial Discharge Measurements

Elektrichestvo, 2021
The article discusses systems developed using an innovative approach to measuring partial discharges, their advantages over traditional methods of monitoring cable lines and electrical equipment, as well as the principles of their operation. The design of the systems is based on a special broadband sensor-antenna which provides remote recording of both
Sergey A. GOLUBTSOV, Roberto CANDELA
openaire   +1 more source

Measuring system for partial discharge

Quality Measurement: The Indispensable Bridge between Theory and Reality (No Measurements? No Science! Joint Conference - 1996: IEEE Instrumentation and Measurement Technology Conference and IMEKO Technical Committee 7. Conference Proceedings, 2002
Measuring of the partial discharge (PD) parameters of the insulating systems is very important. The prompt insulating system estimation and its remaining life time give the great savings. The new, complex PD measuring methods are now developed in the world because conventional methods do not give valid information of the insulating system conditions ...
I. Petkovic   +3 more
openaire   +1 more source

Partial discharge and the measurement in GIS

Conference Record of the 1996 IEEE International Symposium on Electrical Insulation, 2002
The focal point of this paper is to study the partial discharge on-line diagnostic measurement system in GIS from the aspect of electrical measurement assuming that there were not any measurement devices before the GIS being put to use. A length of coaxial cable was wound on a magnetic ring.
null Han Xiaolian   +4 more
openaire   +1 more source

Partial Discharge Measurement and Analysis

2013
Partial Discharge (PD) is a common local defect of high voltage equipment, especially insulation system of transformers. PD in the insulation of electrical equipment is a sign of dielectric defects as well as a cause of further degradation of its insulation system, which may ultimately lead to failure of the apparatus.
Sivaji Chakravorti   +2 more
openaire   +1 more source

Measurements of the energy of partial discharges

Proceedings., Second International Conference on Properties and Applications of Dielectric Materials, 2003
The purpose and the principle of measurements of partial-discharge (PD) energy are described. Two methods of PD energy measurements are presented. The first method gives the discrete values of the energy of PD pulses while the second method realized the averaging of the energy in a specific measurement time.
openaire   +1 more source

Advances in Measuring Partial Discharge in Insulating Liquids

2019 IEEE 20th International Conference on Dielectric Liquids (ICDL), 2019
The IEC 61294 Technical Report, published in 1993, describes a simple test procedure to measure the PD Inception Voltage (PDIV) in insulating liquids and doesn’t cover any other items related to the PD patterns and their evolution at higher voltages. This simplified approach should be considered superseded when taking into account the several studies ...
Calcara, L.   +5 more
openaire   +1 more source

Partial discharges and their measurement

2004
The study of partial discharges is not an academic pursuit. It is driven by a very practical desire, a desire to understand a phenomenon which can be utilised to infer the level of integrity within the insulation systems of high voltage plant and which, in itself, constitutes a serious stress degradation mechanism. The role of partial discharge studies
openaire   +1 more source