A Commentary on Partial Discharge Measurement and Detection
IEEE Transactions on Electrical Insulation, 1987A critical review is presented on the various electrical methods available for partial discharge detection and measurement in terms of their chronological development and application on cable, capacitor, transformer, and machine insulation specimens.
R Bartnikas
exaly +2 more sources
On partial discharge measurement in dielectric liquids
Partial discharge detection in dielectric liquids requires particular PD measurement techniques and instruments. Simultaneous partial discharge (PD) measurements that are employed on insulating liquids, using dual narrow/wide band detectors, are ...
M Pompili, R Bartnikas
exaly +2 more sources
The Nature of the Measurement of Partial Discharge
2019 IEEE International Instrumentation and Measurement Technology Conference (I2MTC), 2019The measurement of partial discharges in solid insulation is predictive of the long-term performance of the insulation. That makes the measurement very important in high-voltage technology. The topic has been of interest for a long time, and has been extensively studied around the world.
Harold Kirkham, D. Rod White
openaire +1 more source
Partial discharge measurements
IEEE Transactions on Dielectrics and Electrical Insulation, 2008[No abstract available]
R. Bartnikas, POMPILI, Massimo
openaire +2 more sources
Equipment for the Energy Measurement of Partial Discharges
IEEE Transactions on Electrical Insulation, 1983The energy dissipated by partial discharges (PD) can be estimated from the U i Q i . It has been described a particular device able to deal with such a calculation using a correlator unit. With gas chromatography analysis a satisfactory correlation was available between the degradation products of liquid (oil) or solid (pressboard) insulation and the ...
G. Garcia, B. Fallou
openaire +1 more source
Measuring the endurance of films in partial discharges
IEEE Transactions on Electrical Insulation, 1993A new test assembly for measuring the endurance of polymeric and ceramic films under the action of partial discharges (PDs) is presented. If experiments are performed under controlled ambient conditions (i.e., relative humidity), the test procedure gives times to breakdown which show low scatter. The effects of different test conditions on the times to
R. Bozzo +2 more
openaire +2 more sources
On line measurement of partial discharges
2000 Annual Report Conference on Electrical Insulation and Dielectric Phenomena (Cat. No.00CH37132), 2002On line measurement of partial discharges of equipment while in service has a great deal of potential in saving equipment down time in gas insulated substations (GIS) and gas insulated transmission lines (GITL). To address this aspect of partial discharge measurement there is scope for considerable progress particularly in the area of cables already is
N. Srinivas, N. Ahmed, G. Raju
openaire +1 more source
Partial discharge and the measurement in GIS
Conference Record of the 1996 IEEE International Symposium on Electrical Insulation, 2002The focal point of this paper is to study the partial discharge on-line diagnostic measurement system in GIS from the aspect of electrical measurement assuming that there were not any measurement devices before the GIS being put to use. A length of coaxial cable was wound on a magnetic ring.
null Han Xiaolian +4 more
openaire +1 more source
2014
This chapter is devoted to the measurement of partial discharges (PD) localized in weak spots of dielectrics if subjected to high test voltages. As standards for PD measurement s have been introduced only for quality assurance tests of HV apparatus energized by power frequency AC voltages (50/60 Hz), the following treatment refers mainly to this test ...
Wolfgang Hauschild, Eberhard Lemke
openaire +1 more source
This chapter is devoted to the measurement of partial discharges (PD) localized in weak spots of dielectrics if subjected to high test voltages. As standards for PD measurement s have been introduced only for quality assurance tests of HV apparatus energized by power frequency AC voltages (50/60 Hz), the following treatment refers mainly to this test ...
Wolfgang Hauschild, Eberhard Lemke
openaire +1 more source