Results 261 to 270 of about 43,696 (308)
Some of the next articles are maybe not open access.
Innovative Solutions for Partial Discharge Measurements
Elektrichestvo, 2021The article discusses systems developed using an innovative approach to measuring partial discharges, their advantages over traditional methods of monitoring cable lines and electrical equipment, as well as the principles of their operation. The design of the systems is based on a special broadband sensor-antenna which provides remote recording of both
Sergey A. GOLUBTSOV, Roberto CANDELA
openaire +1 more source
Measuring system for partial discharge
Quality Measurement: The Indispensable Bridge between Theory and Reality (No Measurements? No Science! Joint Conference - 1996: IEEE Instrumentation and Measurement Technology Conference and IMEKO Technical Committee 7. Conference Proceedings, 2002Measuring of the partial discharge (PD) parameters of the insulating systems is very important. The prompt insulating system estimation and its remaining life time give the great savings. The new, complex PD measuring methods are now developed in the world because conventional methods do not give valid information of the insulating system conditions ...
I. Petkovic +3 more
openaire +1 more source
Advances in Measuring Partial Discharge in Insulating Liquids
2019 IEEE 20th International Conference on Dielectric Liquids (ICDL), 2019The IEC 61294 Technical Report, published in 1993, describes a simple test procedure to measure the PD Inception Voltage (PDIV) in insulating liquids and doesn’t cover any other items related to the PD patterns and their evolution at higher voltages. This simplified approach should be considered superseded when taking into account the several studies ...
Calcara, L. +5 more
openaire +1 more source
Partial Discharge Measurement and Analysis
2013Partial Discharge (PD) is a common local defect of high voltage equipment, especially insulation system of transformers. PD in the insulation of electrical equipment is a sign of dielectric defects as well as a cause of further degradation of its insulation system, which may ultimately lead to failure of the apparatus.
Sivaji Chakravorti +2 more
openaire +1 more source
Measurements of the energy of partial discharges
Proceedings., Second International Conference on Properties and Applications of Dielectric Materials, 2003The purpose and the principle of measurements of partial-discharge (PD) energy are described. Two methods of PD energy measurements are presented. The first method gives the discrete values of the energy of PD pulses while the second method realized the averaging of the energy in a specific measurement time.
openaire +1 more source
Amplitude Analysis in Partial Discharge Measurement
2009 Second International Conference on Advances in Circuits, Electronics and Micro-electronics, 2009In commercial sphere, there is obvious the pursuit of produce electrical wares with high reliability and low risk of breakdown. It is known, the Partial Discharge (PD) is regarded as a parasitic effect occurring in insulating systems. Deep investigation of Partial Discharge activity is necessary for longer service life and better reliability of high ...
Tomas Havlicek +2 more
openaire +1 more source
Partial discharge measurement and interpretation
IEEE Electrical Insulation Magazine, 1988An overview is given of partial discharge patterns, their evaluation, and determination of their origin. Some brief comparisons of test equipment considered to be of general interest are made. The intent is to assist practitioners in the interpretation of results as well as in the accurate discrimination between true partial discharges within an ...
openaire +1 more source
Partial discharges and their measurement
2004The study of partial discharges is not an academic pursuit. It is driven by a very practical desire, a desire to understand a phenomenon which can be utilised to infer the level of integrity within the insulation systems of high voltage plant and which, in itself, constitutes a serious stress degradation mechanism. The role of partial discharge studies
openaire +1 more source
A contribution on the traceability of partial discharge measurements
IEEE Transactions on Electrical Insulation, 1992Commercially used partial discharge (PD) detectors are intended to capture current pulses generated by PD activity in the insulation of a HV test object and then to integrate it, producing a display proportional to the apparent charge. The integration procedure is approximated by a low pass (or bandpass) filter and therefore different partial detectors
P. Osvath, E. Carminati, A. Gandelli
openaire +1 more source
Nature of partial discharges and their measurement
Conference on Electrical Insulation & Dielectric Phenomena — Annual Report 1987, 1987There are perhaps very few measurement techniques that have contributed as much as partial discharge detection in the evaluation of high voltage apparatus, devices and cables. Notwithstanding, the progress that has been achieved over the past several decades in the description and understanding of the various mechanisms that may precipitate electrical ...
openaire +1 more source

