Results 21 to 30 of about 259,888 (302)
Partial Discharge Behaviour of a Protrusion in Gas-Insulated Systems under DC Voltage Stress
High reliability, independence from environmental conditions, and the compact design of gas-insulated systems will lead to a wide application in future high voltage direct current (HVDC) transmission systems.
Thomas Götz +2 more
doaj +1 more source
Low power radiometric partial discharge sensor using composite transistor-reset integrator [PDF]
The measurement of partial discharge provides a means of monitoring insulation health in high-voltage equipment. Traditional partial discharge measurements require separate installation for each item of plant to physically connect sensors with specific ...
Atkinson, Robert C. +10 more
core +2 more sources
The article is aimed to discuss the results of research on the characteristics of partial discharges on defects of different types in high-voltage insulators - on dielectric rod and contact «terminal rod».
D. A. Ivanov
doaj +1 more source
Variability of the Acoustic Emission Signals Generated by Partial Discharges in Mineral Oil
The main purpose of the presented research is to investigate the partial discharge (PD) phenomenon variability under long-term AC voltage with particular consideration of the selected physical quantities changes while measured and registered by acoustic ...
Michał KUNICKI
doaj +1 more source
Beam divergence studies on a hard edge unstable resonators for a long pulse XeCl excimer laser [PDF]
The focusability of a long pulse XeCl excimer laser has been improved using confocal positive branch unstable resonators where the outcoupling is done through the convex mirror. A nearly diffraction limited output beam is obtained from hard edge unstable
Goor, F.A. van +2 more
core +3 more sources
Identifying Prognostic Indicators for Electrical Treeing in Solid Insulation through PD Analysis [PDF]
This paper presents early results from an experimental study of electrical treeing on commercially available pre-formed silicone samples. A needle-plane test arrangement was set up using hypodermic needles.
Binti Ab Aziz, Nur Hakimah +2 more
core +5 more sources
Power transformer (PT), essential equipment in electrical power system proceeds complicated manufacturing process to meet high standard design. During manufacturing process of PT, the drying stage is of importance to remove excessive moisture contaminant
Siswanto +3 more
doaj +1 more source
Partial Discharge Detection Using a Spherical Electromagnetic Sensor
The presence of a partial discharge phenomenon in an electrical apparatus is a warning signal that could determine the failure of the insulation system, terminating the service of the apparatus and/or the network.
Pietro Romano +2 more
doaj +1 more source
Influence of Insulating Material Properties on Partial Discharges at DC Voltage
Understanding a partial discharge mechanism at direct current (DC) is an actual research topic that requires both modeling, simulations and measurements.
Marek Florkowski
doaj +1 more source
Partial discharge (PD) is the primary factor causing insulation degradation in transformers. However, the collected signals of partial discharge are often contaminated with significant noise.
Zhongdong Wu +4 more
doaj +1 more source