DIAGNOSTICS OF OIL-FILLED EQUIPMENT BY MEANS OF REGISTRATION OF PARTIAL DISCHARGES
One of the main tasks of diagnostics of oil-filled equipment is to measure the characteristics of partial discharges in isolation. In the subsequent planning of repairs, assessment of the degree of danger and maintainability of the defect, it becomes ...
G. Y. Kolesnikov
doaj +1 more source
Online partial discharges localization system
In this paper the design and construction of an online non-invasive noninvasive partial discharges (PD) localization system is presented; it is integrated by four equal discone antennas with a wideband of 30 MHz to 1.2 GHz and a central frequency of 615
Primo Alberto Calva Chavarria +2 more
doaj +3 more sources
Improvement of the technical excellence of multiparameter relay protection by combining the signals of the measuring fault detectors using artificial intelligence methods [PDF]
The features of the dielectric rod defects and the rod-electrod defects of polymer insulators were investigated by using the developed complex method of contactless remote diagnostics of high-voltage insulators health, which includes the initial ...
Kulikov A. L. +2 more
doaj +1 more source
Comparative analysis of options for project financing of energy development based on renewable sources [PDF]
The features of the dielectric rod defects and the rod-electrod defects of polymer insulators were investigated by using the developed complex method of contactless remote diagnostics of high-voltage insulators health, which includes the initial ...
Luskatova O. V. +2 more
doaj +1 more source
Partial discharges characteristics study in XLPE cable insulation with multiple defects [PDF]
The paper simulates the electric field intensity picture in the cable with one and several defects. Modeling has shown that the presence of several closely spaced defects does not lead to an increase in the electric field intensity in comparison with
I. V. Komarov +2 more
doaj +1 more source
Effect of partial discharges on the operating condition of high-voltage insulators [PDF]
The features of the dielectric rod defects and the rod-electrod defects of polymer insulators were investigated by using the developed complex method of contactless remote diagnostics of high-voltage insulators health, which includes the initial ...
Golenishchev-Kutuzov A. V. +5 more
doaj +1 more source
Analysis of partial discharges in supporting insulators [PDF]
The diagnostics of overhead power lines is an important issue in the modern electric power industry. Sometimes supporting insulators are destroyed by external factors.
D. A. Polyakov +4 more
doaj +1 more source
Study on the Effect of Void Geometry and Location on Electric Field Distribution and Partial Discharges in HVDC Cables [PDF]
Nowadays HVDC transmission systems are preferred over HVAC systems because of their less power loss and high reliability. In the HVDC cable transmission system, there is a problem of Partial Discharges (PD) occurring due to cavities of the dielectrics in
Subramaniam Sundaramahalingam +2 more
doaj +1 more source
This paper proposes a method for recognising the fault type using a set of diagnostic criteria. Existing approaches to the interpretation of dissolved gas analysis (DGA) results usually rely on single diagnostic criteria.
Oleg Shutenko, Oleksii Kulyk
doaj +1 more source
Modelling of Electrical Discharge Processes for Optimization of Corona-Protection System of High Voltage Rotating Machines Insulation [PDF]
The aim of this work is to study the influence of technological defects in stator windings electri-cal insulation system on the inception of partial discharges in the stator slot of air-cooled electric rotating machines.
Andreev A.M. +5 more
doaj +1 more source

