Results 41 to 50 of about 1,502,407 (287)
Partial Discharge Monitoring in Power Transformers Using Low-Cost Piezoelectric Sensors
Power transformers are crucial in an electric power system. Failures in transformers can affect the quality and cause interruptions in the power supply.
Bruno Castro +6 more
doaj +1 more source
A suitable, non-standard method for artificial pollution testing using simulated acid rain pollution in a laboratory was developed in this work. The method is applicable to a wide range of climatic conditions and rain acidities.
Chibuike Ilomuanya +2 more
doaj +1 more source
Continuous online monitoring of partial discharges in high voltage cables
This paper reviews data acquisition, transmission and processing methodologies for continuous online monitoring of partial discharges in power cable systems.
Tian, Y. +4 more
core +1 more source
Partial discharges measurement by UHF method [PDF]
The unconventional UHF (Ultra High Frequency) method of measuring partial discharges (PD) is based on measuring electromagnetic waves (EM) in the UHF frequency band (300-3000) MHz, using appropriate antennas.
Malešević Nevena +3 more
doaj
Partial discharges can occur in different types of electric equipment and cause progressive insulation deterioration, so there is interest in monitoring partial discharges for assessing the state of the isolation of an electric system and to predict ...
Luís Victor Muller Fabris +1 more
doaj +1 more source
In this work, the extent of natural cleansing effect of rainfall, wind and fog or a combination of these on an insulator string were investigated. Results showed that pollution losses progress with time, with a considerable fraction of losses occurring ...
Chibuike Ilomuanya +2 more
doaj +1 more source
A measurements-based discharge location algorithm for plain disc winding power transformers [PDF]
A measurements-based electrical method for locating partial discharges (PD) in transformers is described in the paper. This location method relies on the series resonance frequencies of the signals produced at the transformer terminals by a discharge on ...
Wang, Zhongdong D. +5 more
core +1 more source
THE PURPOSE of the article is to discuss an updated survey of the technical condition of porcelain high-voltage insulators of the type IOS 110/400, which had defects with partial discharge intensities above 4 nC, at Tatenergo substations. The experiments
V. A. Golenishchev-Kutuzov +5 more
doaj +1 more source
Statistical Analysis of Partial Discharge Characteristics in Transformer Oil at the “Point-Plane” Electrode at Alternating Voltage [PDF]
In this paper, we consider the problems related to measuring and analyzing the characteristics of partial discharges which are the main instrument for oil-filled high-voltage electrical equipment diagnosing.
Korobeynikov S.M. +3 more
doaj
Comparative Tests of Partial Discharges in Nomex® 910 Paper and Cellulose Paper
The article presents the results of comparative investigations of partial discharges in two insulation systems; aramid-enhanced cellulose paper-mineral oil, and pure cellulose paper-mineral oil. Partial discharges were investigated in a diagonal electric
Hubert Moranda +4 more
doaj +1 more source

