Classification of partial discharges
For a long time, classification of partial discharges was performed by eye, by studying discharge patterns at the ellipse of an oscilloscope screen. The introduction of digital processing techniques allowed automation of the recognition procedure. These procedures are reported and applied to a number of actual HV constructions which suffer from partial
Kreuger, F.H. (author) +2 more
exaly +4 more sources
Partial discharge Source Calibration of Radiated Partial Discharge Signals
Based on the IEC 60270 guideline, a galvanic quantification along with free-space radiometry (FSR) method are used to measure partial discharge (PD) simultaneously. The PD source is a floating-electrode emulator type that was custom built. Sources are powered by AC or DC, power supplies. A biconical antenna captures the emitted a signal.
Jaber, Adel +2 more
openaire +1 more source
Separation of radio-frequency sources and localization of partial discharges in noisy environments. [PDF]
Robles G +2 more
europepmc +2 more sources
Modeling partial discharge phenomena
Measurements of partial discharge (PD) activity are a commonly used technique to diagnose the health of insulation material within high voltage plant. The definition of PD is relatively broad, it is generally defined as a localized or confined discharge within an insulating medium [1]. Due to the high electric breakdown strength of insulation materials,
Callender, George, Lewin, Paul
openaire +2 more sources
Improvement of the technical excellence of multiparameter relay protection by combining the signals of the measuring fault detectors using artificial intelligence methods [PDF]
The features of the dielectric rod defects and the rod-electrod defects of polymer insulators were investigated by using the developed complex method of contactless remote diagnostics of high-voltage insulators health, which includes the initial ...
Kulikov A. L. +2 more
doaj +1 more source
Comparative analysis of options for project financing of energy development based on renewable sources [PDF]
The features of the dielectric rod defects and the rod-electrod defects of polymer insulators were investigated by using the developed complex method of contactless remote diagnostics of high-voltage insulators health, which includes the initial ...
Luskatova O. V. +2 more
doaj +1 more source
Partial discharges characteristics study in XLPE cable insulation with multiple defects [PDF]
The paper simulates the electric field intensity picture in the cable with one and several defects. Modeling has shown that the presence of several closely spaced defects does not lead to an increase in the electric field intensity in comparison with
I. V. Komarov +2 more
doaj +1 more source
Effect of partial discharges on the operating condition of high-voltage insulators [PDF]
The features of the dielectric rod defects and the rod-electrod defects of polymer insulators were investigated by using the developed complex method of contactless remote diagnostics of high-voltage insulators health, which includes the initial ...
Golenishchev-Kutuzov A. V. +5 more
doaj +1 more source
Analysis of partial discharges in supporting insulators [PDF]
The diagnostics of overhead power lines is an important issue in the modern electric power industry. Sometimes supporting insulators are destroyed by external factors.
D. A. Polyakov +4 more
doaj +1 more source
This paper proposes a method for recognising the fault type using a set of diagnostic criteria. Existing approaches to the interpretation of dissolved gas analysis (DGA) results usually rely on single diagnostic criteria.
Oleg Shutenko, Oleksii Kulyk