Partial discharges. XII. Partial discharge detection in rotating electrical machines
IEEE Electrical Insulation Magazine, 1992For pt.XI see ibid., vol.8, no.2, p.14 et seq. (1992). Partial discharge (PD) phenomena in the windings of rotating machines are examined. PD measurements on rotating machines, both offline and online, are described. Data acquisition and analysis requirements are briefly considered. >
openaire +1 more source
Microsensors for Partial Discharge
2008 International Conference on Advances in Electronics and Micro-electronics, 2008For longer service life and better reliability of high voltage under stressed parts or of such whole systems, facilities for deep investigation are necessary. Extremely small microsensors which can be integrated during the production inside measured object like high voltage transformers, drivers or high voltage parts of PCB's are, can serve us valued ...
Pavlík Michal, Havlícek Tomas
openaire +1 more source
Partial discharge. XIV. Acoustic partial discharge detection-practical application
IEEE Electrical Insulation Magazine, 1992For pt.XIII see ibid., vol.8, no.4 (July/August 1992). The finer points of acoustic partial discharge (PD) detection systems and their common applications are treated. The PD source, propagation path of the waves, the acoustic sensor, and system noise are described.
openaire +1 more source
2014
This chapter is devoted to the measurement of partial discharges (PD) localized in weak spots of dielectrics if subjected to high test voltages. As standards for PD measurement s have been introduced only for quality assurance tests of HV apparatus energized by power frequency AC voltages (50/60 Hz), the following treatment refers mainly to this test ...
Wolfgang Hauschild, Eberhard Lemke
openaire +1 more source
This chapter is devoted to the measurement of partial discharges (PD) localized in weak spots of dielectrics if subjected to high test voltages. As standards for PD measurement s have been introduced only for quality assurance tests of HV apparatus energized by power frequency AC voltages (50/60 Hz), the following treatment refers mainly to this test ...
Wolfgang Hauschild, Eberhard Lemke
openaire +1 more source
Dynamical properties of partial-discharge patterns
International Journal of Parallel, Emergent and Distributed Systems, 2017AbstractIn this paper, Partial Discharge pattern as an indicator of the fault state of insulation systems of medium voltage overhead lines with covered conductors are described, analyzed, and their dynamical properties are researched. Application of data obtained in natural environment with huge variety of noise interferences, affected by various ...
Marek Lampart +3 more
openaire +1 more source
Partial discharge measurements
2008[No abstract available]
R. Bartnikas, POMPILI, Massimo
openaire +1 more source
Partial discharges and their measurement
2004The study of partial discharges is not an academic pursuit. It is driven by a very practical desire, a desire to understand a phenomenon which can be utilised to infer the level of integrity within the insulation systems of high voltage plant and which, in itself, constitutes a serious stress degradation mechanism. The role of partial discharge studies
openaire +1 more source
Measurements and Analysis of Partial Discharges at HVDC Voltage with AC Components
Energies, 2022Maciej Kuniewski +2 more
exaly