Results 201 to 210 of about 363,979 (334)

Volume staging for arteriovenous malformation SRS treatment using VMAT

open access: yesJournal of Applied Clinical Medical Physics, Volume 23, Issue 12, December 2022., 2022
Abstract Volume staging involves dividing the target volume into smaller parts and treating each part separately. In this study, the feasibility of volume‐staged stereotactic radiosurgery (VS‐SRS) on a linear accelerator using volumetric modulated arc therapy (VMAT) and a frameless patient positioning system is investigated.
Claudia Mendez, Ermias Gete
wiley   +1 more source

Validation of pencil beam scanning proton therapy with multi‐leaf collimator calculated by a commercial Monte Carlo dose engine

open access: yesJournal of Applied Clinical Medical Physics, Volume 23, Issue 12, December 2022., 2022
Abstract This study aimed to evaluate the clinical beam commissioning results and lateral penumbra characteristics of our new pencil beam scanning (PBS) proton therapy using a multi‐leaf collimator (MLC) calculated by use of a commercial Monte Carlo dose engine.
Yuki Tominaga   +5 more
wiley   +1 more source

Utilizing perioperative patient positioning to correct intraocular lens implant subluxation. [PDF]

open access: yesAm J Ophthalmol Case Rep, 2023
Omari A   +4 more
europepmc   +1 more source

CD44v, S1PR1, HER3, MET and cancer‐associated amino acid transporters are promising targets for the pancreatic cancers characterized using mAb

open access: yesFEBS Open Bio, EarlyView.
Novel mAbs could detect cancer‐associated membrane proteins on various type of pancreatic ductal adenocarcinomas (PDAC) by flow cytometry with viable PDAC cells and by immunohistochemistry with PDAC tissues. Results of protein expression were substantiated by mRNA expression by The Cancer Genome Atlas.
Takashi Nakano   +16 more
wiley   +1 more source

Effect of different noise reduction techniques and template matching parameters on markerless tumor tracking using dual‐energy imaging

open access: yesJournal of Applied Clinical Medical Physics, Volume 23, Issue 12, December 2022., 2022
Abstract Purpose To evaluate the impact of various noise reduction algorithms and template matching parameters on the accuracy of markerless tumor tracking (MTT) using dual‐energy (DE) imaging. Methods A Varian TrueBeam linear accelerator was used to acquire a series of alternating 60 and 120 kVp images (over a 180° arc) using fast kV switching, on ...
Mandeep Kaur   +9 more
wiley   +1 more source