Setup of standard PD calibrator and its uncertainties [PDF]

open access: yesJournal of Electrical Engineering and Technology, 2011
The present paper describes the setup of standard partial discharge calibrator for measuring partial discharge and estimating uncertainties. The standard PD calibrator was designed and set up, consisting of a digital pulse generator, capacitor modules, and a digital oscilloscope controlled by software developed in the laboratory.
Sang-Hwa Yi
exaly   +2 more sources

LONG-TERM STABILITY OF Co-C AND Pd-C EUTECTIC FIXED POINTS FOR THERMOCOUPLES CALIBRATION [PDF]

open access: yesMeasuring Equipment and Metrology, 2021
Eutectic fixed points are close to becoming a reference for high temperatures calibration, especially as the new International Temperature Scale (ITS) approach to issue after the re-definition of the Kelvin unit. In this work the long-term stability of Co-C and Pd-C eutectic fixed points were investigated using NIS-Egypt facilities.
Abdelaziz Yasser A.   +2 more
openaire   +2 more sources

Uncertainty assessment on the calibration of Pt/Pd thermocouples at the freezing point of copper

open access: yesProceedings of the 41st SICE Annual Conference. SICE 2002., 2003
For uncertainty assessment on the calibration of Pt/Pd thermocouples at the freezing point of copper, uncertainty components of the automatic ice point for the reference junction, the digital voltmeter, the thermocouple extension wires, and the copper wires were estimated.
Izuchi, Masaya   +4 more
openaire   +1 more source

Calibration of a New Directional Pd-103 Source [PDF]

open access: yesBrachytherapy, 2016
Wesley Culberson   +4 more
openaire   +1 more source

Comparison of partial discharge (PD) calibrators from 0.1 pC to 10 nC

open access: yesMetrologia
Main text High-voltage partial discharge (PD) tests require calibration of PD measurement systems using PD calibrators which provide known values of the apparent charge. A set of travelling reference calibrators was circulated among 14 participating laboratories and each laboratory reported apparent change and rise time measured using ...
J Klüss   +14 more
openaire   +1 more source

Evaluation of a Particle Enhanced Turbidimetric Immunoassay (PETIA) for detecting calprotectin in sputum samples. [PDF]

open access: yesBMC Pulm Med
Förnvik Jonsson M   +5 more
europepmc   +1 more source

Clinical Investigation of Periodontal Health in Smoker and Nonsmoker Individuals. [PDF]

open access: yesInt J Dent
Oweis YG   +8 more
europepmc   +1 more source