A synthetic partial discharge (PD) calibrator has been developed to qualify PD analyzers used for insulation diagnosis of HVAC and HVDC grids including cable systems, AIS, GIS, GIL, power transformers, and HVDC converters.
Abderrahim Khamlichi +2 more
doaj +2 more sources
Partial discharge is one of the main reasons for insulation degradation in high‐voltage apparatuses. Partial discharge is an ineluctable phenomenon that happens when a high electrical field is adjacent to an insulator. High‐frequency current transformers
Hamidreza Besharatifard +3 more
doaj +2 more sources
The correct identification of partial discharges (PDs) is instrumental for the maintenance plan in gas-insulated systems (GIS). However, onsite PD measurements are difficult, especially in HVDC systems, where partial discharges can be confused with ...
Christian Mier +3 more
doaj +2 more sources
Evaluation of Uncertainty in Partial Discharge Measurement: A Case Study
ISO/IEC 17025:2017 recommends all accredited laboratories under this standard, performing testing and calibration, shall identify and evaluate the contributions to the uncertainty of their measurements.
Asif Islam +5 more
doaj +2 more sources
Partial discharge calibrator of a cavity inside high-voltage insulator
This article displayed the method of partial discharge (PD) measurement in high-voltage insulator and calibrating the effective element (capacitor) to enhance the PD signal.
Hamoodi Ali N. +2 more
doaj +1 more source
A comparative study on partial discharge emulators. [PDF]
Partial Discharge (PD) detection plays a vital role in electrical power stations, it can help protecting the high voltage equipment, it can prevent explosion of these equipment and hence preventing a catastrophic failure. PD detection can be performed in
Mahmud A. Yusuf +14 more
core +1 more source
Partial discharge detection on power equipment using a magneto-resistive sensor
Partial discharges (PD) detection is an effective diagnostic method to assess the insulation condition of electrical power equipment in the high-voltage laboratory or field tests.
Ghaffarian Niasar, M. (author) +9 more
core +1 more source
Precise calibration of LIGO test mass actuators using photon radiation pressure [PDF]
Precise calibration of kilometer-scale interferometric gravitational wave detectors is crucial for source localization and waveform reconstruction. A technique that uses the radiation pressure of a power-modulated auxiliary laser to induce calibrated ...
Kawabe, K. +14 more
core +1 more source
A one-way ANOVA and tukey-kramer post-hoc analysis was used to compare PD patients with HC, MSA and PSP controls separately. Fold change values relative to a calibrator are displayed with error bars indicating SEM. Gapdh mRNA was used as a reference gene
Bernard M. Ravina (141224) +4 more
core +1 more source
The location of partial discharges in a power transformer can be determined based on the characteristics of the transfer function from the discharge source to the measuring terminal.
Crossley, P.A. +5 more
core +1 more source