Results 131 to 140 of about 1,324,187 (295)
ABSTRACT Background Quantitative Flow Ratio (QFR) is a well‐established, non‐hyperemic, angiographic, wire‐free predictor of ischemia when compared to Fractional Flow Reserve (FFR). However, its diagnostic accuracy at low frame rates (< 10 frames/second), commonly used in contemporary practice to minimize radiation exposure, has not been evaluated ...
Joseph M. O'Brien +13 more
wiley +1 more source
Clinical Outcomes of Drug‐Eluting Stents and Drug‐Coated Balloons in Tortuous Small Coronary Lesions
ABSTRACT Background In small, tortuous coronary lesions, the long‐term comparative performance of drug‐coated balloon (DCB) angioplasty versus drug‐eluting stent (DES) treatment remains uncertain, despite both strategies being widely used in contemporary percutaneous coronary intervention (PCI) practice. Aims This study aimed to compare 3‐year clinical
Shunichiro Ishio +6 more
wiley +1 more source
ABSTRACT Background Optimal stent expansion is a key determinant of long‐term outcomes after PCI. Intravascular imaging provides the most accurate assessment of stent deployment but remains underused, especially in older patients with MI and multivessel disease.
Marta Cocco +12 more
wiley +1 more source
Healthcare Professional’s Attitudes Toward Male Nurses Working in the Context of Pediatric Care
To examine the attitudes of healthcare professionals (HCPs) toward male nurses working in the context of pediatric care. This cross-sectional quantitative using purposeful sampling of 135 participants.
Maryam A. Ageeli MSN, RN +1 more
doaj +1 more source
ABSTRACT We present a 66‐year‐old undergoing ostial‐to‐mid right coronary artery (RCA) percutaneous coronary intervention (PCI) lesion proximal to an existing stent in the mid‐to‐distal segment. The patient underwent PCI, with intravascular imaging using the Novasight Hybrid IVUS OCT (Conavi, Toronto, CA) which revealed a proximal edge dissection and ...
Natali Sorajja +3 more
wiley +1 more source
ABSTRACT Background Despite recommendations in international guidelines, Intracoronary pressure wire assessment (PWA) utilization remains limited in clinical practice. This study aims to describe (i) trends of PWA during Percutaneous coronary interventional (PCI), (ii) factors that predict its application, and (iii) association with in‐hospital ...
Hussein Bashar +3 more
wiley +1 more source
ABSTRACT Background Limited data are available on the use of intravascular ultrasound (IVUS) in patients presenting with ST‐segment elevation myocardial infarction (STEMI). Aims This study aimed to assess the impact of IVUS‐guided primary percutaneous coronary intervention (PCI).
Frederik T. W. Groenland +13 more
wiley +1 more source
ABSTRACT Background Transcatheter aortic valve implantation (TAVI) with the Acurate Neo has been linked to a significant incidence of paravalvular leakage (PVL), addressed by the Acurate Neo 2 incorporating an active sealing skirt. Recent findings suggest that midframe under‐expansion is associated with worse outcomes.
Lisa Crusius +9 more
wiley +1 more source
ABSTRACT Background Transcatheter closure (TCC) of sinus venosus defects (SVD) using balloon‐expandable covered stents is an emerging alternative to surgery. ZephyrCS (Sahajanand Laser Technologies, Gandhinagar, India) is available in long lengths to suit SVD closure.
Pramod Sagar +3 more
wiley +1 more source