Results 41 to 50 of about 60,729 (181)
Quantitative Anatomy of C7 Vertebra in Southern Chinese for Insertion of Lateral Mass Screws and Pedicle Screws [PDF]
Study DesignRetrospective study.PurposeTo analyze the quantitative anatomy of C7 vertebra for insertion of lateral mass screws and pedicle screws in Southern Chinese patients.Overview of LiteratureC7 lateral mass is smaller when compared to other ...
Michael Siu Hei Tse +3 more
doaj +1 more source
The presence of thick sub-cutaneous fat and bulky paraspinal musculature mandates extensive surgical dissection in obese patients undergoing open Transforaminal lumbar interbody fusion surgery.
Rishi M. Kanna +2 more
doaj +1 more source
ABSTRACT The azygos vein (AV) is typically described as ascending vertically to the right of the vertebral column before arching anteriorly to drain into the superior vena cava. However, a small number of studies suggest that it is found leftward in older adults.
Lauren R. Hector +4 more
wiley +1 more source
Subperiosteal circumferential connective tissue graft for vertical implant soft tissue augmentation
Abstract Background Vertical implant soft tissue augmentation is indicated to optimize esthetic outcomes in cases of peri‐implant soft tissue deficiency or dehiscence, particularly when the peri‐implant mucosa is exposed during a full smile. This manuscript describes the use of a subperiosteal circumferential connective tissue graft (SC CTG) for ...
Jonathan H. Do, Alex S. Kim
wiley +1 more source
The Pullout Strength of Pedicle Screws Following Redirection After Lateral Wall Breach or End-plate Breach [PDF]
Screw malposition, such as lateral wall breach or end-plate breach, is one of the main pitfalls of inserting pedicle screws. Methods: From 17 fresh spines 54 vertebrae were harvested.
Kobayashi, Takuma +34 more
core
Different-sized screws were chosen and randomly implanted into each pedicle of the vertebrae by an experienced surgeon, 6.0 mm × 45 mm, 6.0 mm × 50 mm, and 6.5 mm × 45 mm screws were inserted sequentially into the semi-pedicle (left side of A, B, C) and ...
Ming-Kai Hsieh (6894410) +6 more
core +1 more source
Background The mechanical stability of lumbar transpedicular dynamic stabilization (LTDS) was determined by simulating the degree to which the pedicle screws penetrated the lateral pedicle cortex.
Chen Zhao +5 more
doaj +1 more source
A Biomechanical Comparison of Expansive Pedicle Screws for Severe Osteoporosis: The Effects of Screw Design and Cement Augmentation. [PDF]
Expansive pedicle screws significantly improve fixation strength in osteoporotic spines. However, the previous literature does not adequately address the effects of the number of lengthwise slits and the extent of screw expansion on the strength of the ...
Ching-Lung Tai +5 more
doaj +1 more source
Abstract Purpose To compare the iliotibial band autograft biologically augmented with gracilis (ITBAG) technique with a hamstring tendon autograft combined with extra‐articular lateral tenodesis using fascia lata (HT‐LET), in terms of (1) return‐to‐sport rates, (2) patient‐reported functional outcomes and (3) complication rates.
Alexandre Le Guen +9 more
wiley +1 more source
Stability of Pedicle Screws After Kyphoplasty Augmentation
Objective: The goal of this cadaver study was to compare the stability of pedicle screws after implantation in soft or cured kyphoplasty cement. Methods: Pedicle screws were inserted in a total of 30 thoracolumbar vertebrae of 10 different human ...
Lüring, Christian +11 more
core +1 more source

