Effects of spot parameters in pencil beam scanning treatment planning

Medical Physics, 2017
BackgroundSpot size σ (in air at isocenter), interspot spacing d, and spot charge q influence dose delivery efficiency and plan quality in Intensity Modulated Proton Therapy (IMPT) treatment planning. The choice and range of parameters varies among different manufacturers.
Aafke Christine, Kraan   +5 more
openaire   +2 more sources

Development of Pencil Beam Scanning Nozzle System

2009
Purpose: Several types of pencil beam scanning system for proton therapy have been developed and applied to clinical treatment. In case of pencil beam scanning using cyclotron as the proton source, it is common to use continuous scanning method. Then scanning speed and beam current are modulated simultaneously[for full text, please go to the a.m. URL]
Asaba, T   +5 more
openaire   +2 more sources

Proton FLASH: passive scattering or pencil beam scanning?

Physics in Medicine & Biology, 2021
Abstract This study focused on a direct comparison of dose delivery efficiency between two proton FLASH delivery modes: passive scattering and pencil beam scanning (PBS). Monte-Carlo simulation of the beamline was performed using the Geant4 package. Two proton energies (63 and 230 MeV) were selected, targeting for
Guoliang Zhang   +3 more
openaire   +2 more sources

Experimentally validated pencil beam scanning source model in TOPAS

Physics in Medicine and Biology, 2014
The presence of a low-dose envelope, or 'halo', in the fluence profile of a proton spot can increase the output of a pencil beam scanning field by over 10%. This study evaluated whether the Monte Carlo simulation code, TOPAS 1.0-beta 8, based on Geant4.9.6 with its default physics list, can predict the spot halo at depth in phantom by incorporating a ...
Liyong, Lin   +4 more
openaire   +2 more sources

Dosimetric consequences of pencil beam width variations in scanned beam particle therapy

Physics in Medicine and Biology, 2013
Scanned ion beam delivery enables the highest degree of target dose conformation attainable in external beam radiotherapy. Nominal pencil beam widths (spot sizes) are recorded during treatment planning system commissioning. Due to changes in the beam-line optics, the actual spot sizes may differ from these commissioning values, leading to differences ...
M A, Chanrion   +4 more
openaire   +2 more sources

Proton pencil beam scanning for mediastinal lymphoma: the impact of interplay between target motion and beam scanning

Physics in Medicine and Biology, 2015
The purpose of this study was to assess the feasibility of proton pencil beam scanning (PBS) for the treatment of mediastinal lymphoma. A group of 7 patients of varying tumor size (100-800 cc) were planned using a PBS anterior field. We investigated 17 fractions of 1.8 Gy(RBE) to deliver 30.6 Gy(RBE) to the internal target volume (ITV).
C, Zeng   +6 more
openaire   +2 more sources

Investigation of scan path optimization in improving proton pencil beam scanning continuous delivery

Physics in Medicine & Biology, 2023
Abstract Objective . To investigate the impact of scan path optimization on the dose accuracy and beam delivery time (BDT) of proton pencil beam scanning in the dose-driven continuous scanning (DDCS). Approach .
Chunbo Liu   +8 more
openaire   +2 more sources

Parametric Synthesis of Well-Scanning Isophoric Pencil Beams

IEEE Transactions on Antennas and Propagation, 2017
Interest in uniformly illuminated (isophoric) density-tapered planar antenna arrays has recently revived. For arrays consisting of concentric rings of elements, we present a nonstochastic algorithm that calculates ring radii for generation of pencil beams without the need for prior specification of the number of rings.
Salas-Sanchez, AA   +3 more
openaire   +2 more sources

Multi-purpose nozzle for pencil beam scanning and wobbling

2009
PTCOG 48; Meeting of the Particle Therapy Co-Operative ...
Tachikawa, T   +5 more
openaire   +2 more sources

Clinical Pencil Beam Scanning: Present and Future Practices

2016
Pencil beam scanning (PBS) is the most advanced beam delivery technology in particle therapy nowadays. After a pioneering phase, PBS is rapidly becoming available on a larger scale worlwide, and is expected to be the standard beam delivery technique in the future to come.
Marco Schwarz   +7 more
openaire   +1 more source