Measurement of central corneal thickness by ultrasonic pachymeter and oculus pentacam in patients with well-controlled glaucoma: hospital-based comparative study

open access: yesClinical Ophthalmology, 2016
Riyam Faihan Rashid, Qasim K Farhood Department of Ophthalmology, College of Medicine, University of Babylon, Babylon, Iraq Background: The measurement of central corneal thickness (CCT) plays an important role in the diagnosis and treatment of ...
Rashid RF, Farhood QK
doaj  

Repeatability and agreement of two scheimpflug-based imaging systems for anterior segment parameters in keratoconus

open access: yesJournal of the Egyptian Ophthalmological Society
Purpose To assess the agreement between the Pentacam HR and the Sirius Scheimpflug analyzer in the anterior chamber, topographic, and corneal aberration parameters and to assess the repeatability of the measurements of each device in patients with ...
Doaa M. Ashour   +3 more
doaj   +1 more source

Agreement between Lenstar and Pentacam in Keratometry and Anterior Chamber Depth Measurements [PDF]

open access: yes, 2018
Purpose:  To compare keratometry and anterior chamber depth (ACD) measurements performed using Lenstar LS 900 (Haag-Streit AG, Switzerland) and the Pentacam (Oculus, Weltzar, Germany) devices in healthy eyes.Method: Sixty eyes of 30 healthy volunteers ...
Agha Mirsalim, Mohammad Reza   +4 more
core   +1 more source

Differences between the parameters measured with Pentacam among the patient groups.

open access: yes, 2016
Differences between the parameters measured with Pentacam among the patient groups.
Dorottya Pásztor (2609566)   +7 more
core   +1 more source

Agreement between Corneal Thickness Measurements Using Pentacam Scheimpflug Camera, Noncontact Specular Microscopy, and Ultrasonographic Pachymetry in Diabetic Patients

open access: yes, 2017
Purpose: To evaluate the agreement of corneal thickness (CT) measurements obtained by the Pentacam Scheimpflug camera, noncontact specular microscopy (SM), and ultrasonographic pachymetry (UP) in diabetic (DM) patients; and whether duration of diabetes ...
Ornek, Firdevs   +5 more
core   +1 more source

Evaluation of progression of keratoconus using pentacam [PDF]

open access: yes, 2015
AIM OF THE STUDY: To evaluate the progression of keratoconus using pentacam. METHODS: A Hospital based prospective study where patients were recruited from March 2013 to March 2014 and were followed up for a minimum period of 6 months.
Sundar, T
core  

Central Corneal Thickness Measurements in Unoperated Eyes and Eyes After PRK For Myopia Using Pentacam, Orbscan II, and Ultrasonic Pachymetry

open access: yes, 2007
PURPOSE: To compare central corneal thickness measurements obtained in unoperated eyes and eyes after myopic photorefractive keratectomy (PRK) using a rotating Scheimpflug camera (Pentacam), a scanning slit corneal topography system (Orbscan II), and ...
김태임, 김응권
core   +1 more source

Repeatability of IOL decentration measured by Pentacam and IOL decentration outcomes of OPD-Scan III.

open access: yes
Repeatability of IOL decentration measured by Pentacam and IOL decentration outcomes of OPD-Scan III.
Qiong Li (346270)   +5 more
core   +1 more source

Repeatability of Pentacam peripheral corneal thickness measurements

open access: yes, 2015
Purpose: To assess the repeatability of corneal thickness (CT) measurements, along the horizontal meridian up to 5. mm from centre, in healthy eyes with the Pentacam instrument.
Martin, Raul   +3 more
core   +1 more source

Comparison of central corneal thickness, thinnest corneal thickness, anterior chamber depth, and simulated keratometry using Galilei, Pentacam, and Sirius devices

open access: yes, 2014
Purpose: The aim was to evaluate the agreement in the central corneal thickness (CCT), thinnest corneal thickness (TCT), anterior chamber depth (ACD), and mean simulated keratometry (simK) measurements using Pentacam, Galilei, and Sirius Scheimpflug ...
Yilmazoglu, Meltem   +13 more
core   +1 more source