Calculation of the Real Corneal Refractive Power after Photorefractive Keratectomy Using Pentacam, When Only the Preoperative Refractive Error is Known

open access: yesJournal of Ophthalmology, 2020
Purpose. To check if a regression formula, IOLMaster-derived, to calculate the real corneal power after photorefractive keratectomy (PRK), can give reliable results utilizing the Pentacam. Methods.
Maddalena De Bernardo   +3 more
doaj   +1 more source

Pentacam changes in primary angle-closure glaucoma after different lines of treatment [PDF]

open access: yesInternational Journal of Ophthalmology, 2020
AIM: To assess the changes in the anterior chamber parameters using Pentacam following four different lines of treatment of primary angle-closure glaucoma (PACG).
Tharwat H. Mokbel   +6 more
doaj   +1 more source

Comparative study between specular microscopy, pentacam and anterior segment optical coherence tomography in assessment of central corneal thickness [PDF]

open access: yesAl-Azhar International Medical Journal, 2022
Background; Central corneal thickness (CCT) measurements are important for determining intraocular pressure (IOP), examining corneal endothelium activity, and assessing patients before and after refractive surgery . Contact and non-contact techniques can
Mahmoud Ali, Hassan Hegazy, Ahmad Farid
doaj   +1 more source

Comparison of Javal-Schiøtz keratometer, Orbscan IIz and Pentacam topographers in evaluating anterior corneal topography

open access: yes, 2023
Clinical relevance: Inter-instrument variation in anterior corneal shape (ACS) measurement has a consequence for ocular clinical practice. Background: To consider inter-instrument variability in keratometry measurements across the ACS and to explore ...
Purslow, Christine   +5 more
core   +1 more source

Repeatability and Agreement of Central Corneal Thickness and Keratometry Measurements between Four Different Devices

open access: yesJournal of Ophthalmology, 2017
Background. To estimate repeatability and comparability of central corneal thickness (CCT) and keratometry measurements obtained by four different devices in healthy eyes. Methods.
Laszlo Kiraly   +3 more
doaj   +1 more source

Adjusted CCT and TCT differences between Pentacam and ASOCT.

open access: yes, 2020
Adjusted CCT and TCT differences between Pentacam and ASOCT.
Maria Karasawa (8394108)   +9 more
core   +1 more source

Eficacia del Orbscan II y Pentacam en la evaluación de los mapas de elevación en candidatos a cirugía refractiva mediante un análisis de repetibilidad [PDF]

open access: yes, 2009
Introduction: Anterior and posterior corneal elevations are measurements used to detect keratoconus suspects.Purpose: To determine the efficacy of Orbscan II® and Pentacam® when assessing their elevation maps.Materials and methods: The efficacy ...
Blanco, Claudia   +3 more
core   +1 more source

Biometric measurements with CASIA 2, Pentacam AXL, and IOLMaster 700 in normal participants.

open access: yes, 2022
Biometric measurements with CASIA 2, Pentacam AXL, and IOLMaster 700 in normal participants.
Rosepon Asawaworarit (12621802)   +3 more
core   +1 more source

The Pentacam® AXL Wave provides a reliable wavefront-based objective refraction when compared to manifest subjective refraction: A prospective study

open access: yesIndian Journal of Ophthalmology, 2022
Purpose: Accurate refraction is arguably the most important parameter for a successful laser vision correction surgery and is based on a combination of manifest and cycloplegic refraction.
Kepa Balparda   +3 more
doaj   +1 more source

Differences between estimated postoperative corneal power (K) from 4-mm Orbscan IIz and Pentacam.

open access: yes, 2015
aEstimated corneal power derived from 4.0 mm TOP was used as a reference.ΔKOrb 4 = KOrbscan IIz at 4-mm—KPentacam, CI = confidence interval, LoA = limits of agreement, TOP = total optical power from Orbscan IIz, EKR = equivalent keratometric readings ...
Kaevalin Lekhanont (718791)   +3 more
core   +1 more source