Results 101 to 110 of about 127,368 (296)
“ETOX pH SENSOR” AS pH MEASURING ELECTRODE
In this paper we show that the electrode by d.c. reactive sputtering of irridiuim oxide on the solid substrates have utility for pH sensing. We named this electrode METOX pH Sensor in order to distinguish from Glass Electrode. METOX pH Sensor had linear response over a range of 0 to 14 and Nernstian slope 59.15 mV/pH. For long-term stability in aqueous
AKIHIKO KATO +6 more
openaire +2 more sources
Ascidian Ciona larvae initially show strong clockwise tail twisting, which is largely corrected during development. However, a small residual twist remains. This study shows that organized helical myofibrils in tail muscles mechanically stabilize this residual asymmetry, preventing complete restoration of bilateral symmetry and revealing how embryos ...
Yuki S. Kogure +3 more
wiley +1 more source
Fluorescent carbon dioxide indicators
Over the last decade, fluorescence has become the dominant tool in biotechnology and medical imaging. These exciting advances have been underpinned by the advances in time-resolved techniques and instrumentation, probe design, chemical / biochemical ...
Hodgen, S. +4 more
core +1 more source
Degradation mechanism of the von Willebrand factor A2 domain by nattokinase
Nattokinase, a natto‐derived protease, exhibits potent antithrombotic effects. This study demonstrates that nattokinase directly cleaves the von Willebrand factor (vWF) A2 domain in vitro. Unlike the native regulator ADAMTS13, nattokinase degrades folded vWF independently of shear stress.
Ryuichi Hyakumoto +3 more
wiley +1 more source
Modulation of Homer1 EVH1 domain internal dynamics by putative autism‐associated mutations
The putative autism‐associated M65I and S97L variants of the EVH1 domain of the postsynaptic scaffold protein Homer1 do not exhibit substantial changes in their overall structure or partner binding. Both of them, but especially the M65I variant, show altered internal dynamics relative to the wild‐type domain on the μs‐ms timescale, indicated by the ...
Fanni Farkas +6 more
wiley +1 more source
PH-monitoring in mortar with thermally-oxidized iridium electrodes
The pH of the concrete pore solution plays a vital role in protecting the reinforcing steel from corrosion. Here, we present results from embeddable pH sensors that permit the continuous, in-situ monitoring of the pH in the concrete pore solution.
Yurena Seguí Femenias +2 more
doaj +1 more source
Sol–gel-entrapped pH indicator for monitoring pH variations in cementitious materials
Sensors for pH evaluation of concrete were made by a sol–gel process with alizarin yellow as pH indicator. The optical absorbance was measured with a visible spectrophotometer coupled with optical fibers.
Barbara Inserra +3 more
doaj +1 more source
The pH sensor for flavivirus membrane fusion [PDF]
Viruses that infect cells by uptake through endosomes have generally evolved to “sense” the local pH as part of the mechanism by which they penetrate into the cytosol. Even for the very well studied fusion proteins of enveloped viruses, identification of the specific pH sensor has been a challenge, one that has now been met successfully, for ...
openaire +2 more sources
The ubiquitin‐proteasome system and autophagy as guardians of the cellular proteome
This Perspective covers the three principles governing the crosstalk between the ubiquitin‐proteasome system and autophagy in cellular proteostasis: (1) a shared ubiquitin code routing substrates via shuttle factors or autophagy receptors; (2) spatial compartmentalization into phase‐separated degradation hubs and organelle‐specific modules (exemplified
Ivan Dikic
wiley +1 more source
pH-sensitive fluorescent proteins have revolutionized the field of cellular imaging and physiology, offering insight into the dynamic pH changes that underlie fundamental cellular processes. This comprehensive review explores the diverse applications and
Shu-Ang Li +10 more
doaj +1 more source

