Results 121 to 130 of about 2,339,090 (251)
Advance in CO_(2) and pH Fiber Optic Chemical Sensors
本文简述了CO2和pH光纤化学传感器的最新研究进展,重点介绍了用于环境监测的基于pH指示剂的CO2和pH传感器。This paper reviews the recent progress in the development of CO_(2) and pH fiber optic chemical sensors with a focus on the pH-sensitive reagent-based optical chemical sensors.国家863计划(No ...
陈进顺, 鲁中明, 许昆明
core
Loss of NAPRT promotes lung tumor initiation and growth through a noncanonical mechanism, independent of its role in NAD+ biosynthesis. Mechanistically, NAPRT depletion activates the mTORC2‐driven AKT/β‐catenin signaling axis to enhance clonogenic and invasive phenotypes. Furthermore, lung‐specific Naprt deletion significantly increases tumor burden in
Myung Joon Oh +11 more
wiley +1 more source
Halochromic textile materials as innovative pH-sensors
Recently, an increasing interest in pH-sensitive textiles is recognized. These chromic textiles can be used as flexible sensors for various applications.
De Clerck, Karen +3 more
core +1 more source
In head and neck squamous cell carcinoma (HNSCC) p53 and p63 exert opposite roles on the transcription regulation of the lncRNA NEAT1. Under basal conditions, p53 levels are low and p63 represses NEAT1 expression. Upon genotoxic stress, p53 is rapidly induced, displacing p63 from the NEAT1 promoter leading to NEAT1 transcriptional activation and ...
Sara De Domenico +5 more
wiley +1 more source
Taxanes are widely used chemotherapeutics whose effects on cellular mechanics remain poorly understood. We show that paclitaxel induces rapid cellular contraction by promoting GEF‐H1 dissociation from microtubules and non‐muscle myosin II activation through RhoA/ROCK.
Gloria Asensio‐Juárez +5 more
wiley +1 more source
Effects of pH on High-Performance ZnO Resistive Humidity Sensors Using One-Step Synthesis
In this paper, we prepared a high-performance zinc oxide (ZnO) humidity sensor in an alkaline environment using one-step hydrothermal method. Experiments showed that the pH value of the precursor solution affects the performance of ZnO humidity sensors ...
Jun Zhang +3 more
core +1 more source
Isocitrate dehydrogenase 1 (IDH1) mutations are highly recurrent in multiple human cancer types, including cholangiocarcinoma and glioma. IDH1 R132C is the most common IDH1 mutation in cholangiocarcinoma and likely arises from APOBEC3A‐ or APOBEC3B‐mediated deamination.
Kelly E. Butler +3 more
wiley +1 more source
(1) Background: This study validates multichannel impedance/pH (MII/pH) sensors to measure oesophageal impedance transit (EZT). (2) Methods: EZT involved patients rapidly drinking 200 mL of saline during their MII/pH test.
Terry Wong +3 more
core +1 more source
Review on state-of-the-art in polymer based pH sensors
This paper reviews current state-of-the-art methods of measuring pH levels that are based on polymer materials. These include polymer-coated fibre optic sensors, devices with electrodes modified with pH-sensitive polymers, fluorescent pH indicators ...
Olga Korostynska (12581593) +7 more
core +1 more source
Negative Capacitance Dual-Gated ISFETs as Ultra-Sensitive pH Sensors
Fahimul Islam Sakib +3 more
doaj +1 more source

