Results 61 to 70 of about 3,971 (201)
Visual acuity analysis on the phakic lenses implantation in high myopia [PDF]
Introdução – Na correção de miopias elevadas, a cirurgia por implante de lente intraocular fáquica tem tido progressivamente uma maior adesão em relação à cirurgia por laser.
Alves, Neusa +4 more
core
ABSTRACT Objective To describe the clinical outcome of intravitreal cidofovir injection for palliative management of refractory end‐stage glaucoma and vision loss in silicone oil‐filled eyes following retinal reattachment surgery in dogs. Procedures Medical records of dogs that underwent a single intravitreal cidofovir injection for pharmacologic ...
Sunhyo Kim, Jaeho Shim
wiley +1 more source
Intraocular lenses in age-related macular degeneration [PDF]
Purpose: The aim of this work is to review the lenses, assessing their advantages and disadvantages. We describe a total of seven types of intraocular lenses (IOLs) recommended for age-related macular degeneration (AMD).
A Agarwal +30 more
core +1 more source
A review of angle kappa and multifocal intraocular lenses and their effect on visual outcomes
Abstract Although most patients are satisfied with their vision after multifocal intraocular lens (IOL) implantation, dissatisfaction has been reported for various reasons, including poor visual outcomes and visual disturbances. Many published reports hypothesise that preoperative angle kappa may be an associated factor in patient dissatisfaction ...
Thomas Kohnen +2 more
wiley +1 more source
Artiflex versus STAAR® implantable contact lenses for correction of high myopia
Purpose : To compare two phakic intraocular lenses, Artiflex and STAAR® implantable contact lens (ICL), in high myopia. Setting : Isfahan Ophthalmology Clinic, Iran.
Mohammad Ghoreishi +5 more
doaj +1 more source
Abstract Purpose To investigate the precision and accuracy performance of a two‐step approach for optimizing lens formula constants (FC) with a refractive offset correction (RO) as a second tuning parameter. Methods Using IOLMaster 700 biometric data from 4 datasets (886/613/821/467 eyes treated with the Hoya Vivinex/Johnson&Johnson ZCB00/Alcon SA60AT ...
Achim Langenbucher +5 more
wiley +1 more source
Clinical and material degradations of intraocular lenses: A review [PDF]
Purpose: To review the published scientific literature concerning clinical and material degradations of intraocular lenses after implantation in cataract surgery.
Hull, C. +2 more
core +1 more source
Abstract Purpose To estimate the risk of rhegmatogenous retinal detachment (RRD) following pars plana vitrectomy (PPV) for full‐thickness macular hole (FTMH) or epiretinal membrane (ERM) in pseudophakic eyes. Methods We conducted a nationwide Danish registry‐based cohort study from 2010 to 2023.
Birgitte Romme Nielsen +6 more
wiley +1 more source
Ceratoprótese de Boston tipo I: Revisão [PDF]
Regardless of significant progress in the field of corneal transplantation to treat corneal opacification, some cases of corneal blindness still present a poor prognosis for conventional penetrating keratoplasty.
Magalhães, Fernanda Pedreira +2 more
core +2 more sources
Nationwide trends in macular hole, epiretinal membrane and floaters surgery, 2010–2023
Abstract Purpose To examine the incidence of pars plana vitrectomy (PPV) for full‐thickness macular hole (FTMH), epiretinal membrane (ERM) and floaters over time and across regions in Denmark. Methods This nationwide registry‐based study included all patients undergoing PPV for FTMH, ERM, or floaters in Denmark from 2010 to 2023.
Birgitte Romme Nielsen +4 more
wiley +1 more source

