Results 61 to 70 of about 57,882 (315)

Dietary Protein Intake and Peritoneal Protein Losses in Peritoneal Dialysis Patients

open access: yesTherapeutic Apheresis and Dialysis, EarlyView.
ABSTRACT Introduction Peritoneal dialysis (PD) patients lose protein in their waste dialysate, potentially increasing their risk for malnutrition. We wished to determine whether there was any association between losses and dietary protein intake (DPI). Methods DPI was assessed from 24‐h dietary recall using Nutrics software.
Haalah Shaaker, Andrew Davenport
wiley   +1 more source

Effects of the Fluid Replacement Method During Online Hemodiafiltration on the Solute Removal Performance and Biocompatibility Using the Asymmetric Cellulose Triacetate Membrane

open access: yesTherapeutic Apheresis and Dialysis, EarlyView.
ABSTRACT Introduction Pre‐dilution online hemodiafiltration (Pre‐HDF) is predominantly used in Japan, whereas post‐dilution online HDF (Post‐HDF) is more common in Europe. An asymmetric cellulose triacetate (ATA) membrane may improve biocompatibility.
Kenji Sakurai   +4 more
wiley   +1 more source

Ultrasound Shear Wave Elastography and Transient Optical Coherence Elastography: Side-by-Side Comparison of Repeatability and Accuracy

open access: yesIEEE Open Journal of Engineering in Medicine and Biology, 2021
Objective: We compare the repeatability and accuracy of ultrasound shear wave elastography (USE) and transient optical coherence elastography (OCE). Methods: Elastic wave speed in gelatin phantoms and chicken breast was measured with USE and OCE and ...
Justin R. Rippy   +3 more
doaj   +1 more source

A Bibliometric Analysis of Publications in Uremic Toxins From 1991 to 2024

open access: yesTherapeutic Apheresis and Dialysis, EarlyView.
ABSTRACT Background Uremic toxins are a growing area of research in nephrology, with significant implications in the progression and treatment of chronic kidney disease (CKD) and the management of end‐stage kidney disease (ESKD). This bibliometric analysis aims to evaluate the global research trends, key contributors, and the impact of publications in ...
Yuh‐Shan Ho   +7 more
wiley   +1 more source

Robustness of Deep Learning Algorithm to Varying Imaging Conditions in Detecting Low Contrast Objects in Computed Tomography Phantom Images: In Comparison to 12 Radiologists

open access: yesDiagnostics, 2021
The performance of deep learning algorithm (DLA) to that of radiologists was compared in detecting low contrast objects in CT phantom images under various imaging conditions. For training, 10,000 images were created using American College of Radiology CT
Hae Young Kim   +8 more
doaj   +1 more source

PHANTOM TUMOUR. [PDF]

open access: yesThe Lancet, 1881
n ...
openaire   +2 more sources

Effectiveness of a Novel Low‐Density Lipoprotein Apheresis Device Rheocarna in Patients Undergoing Hemodialysis With Chronic Limb‐Threatening Ischemia: A Single‐Center Retrospective Study

open access: yesTherapeutic Apheresis and Dialysis, EarlyView.
ABSTRACT Background Chronic limb‐threatening ischemia (CLTI) is a severe form of lower‐extremity artery disease characterized by distal lesions and microcirculatory impairment, limiting revascularization efficacy. Rheocarna is a direct hemoperfusion low‐density lipoprotein (LDL) adsorption device with potential rheological and anti‐inflammatory ...
Kunihiro Ishioka   +12 more
wiley   +1 more source

Use of 3D printed materials as tissue-equivalent phantoms

open access: yes, 2015
This study used the specific example of 3D printing with acrylonitrile butadiene styrene (ABS) as a means to investigate the potential usefulness of benchtop rapid prototyping as a technique for producing patient specific phantoms for radiotherapy ...
Markwell, T.   +8 more
core   +1 more source

Estimation of the Proton Resonance Frequency Coefficient in Agar-based Phantoms

open access: yesJournal of Medical Physics
Aim: Agar-based phantoms are popular in high intensity focused ultrasound (HIFU) studies, with magnetic resonance imaging (MRI) preferred for guidance since it provides temperature monitoring by proton resonance frequency (PRF) shift magnetic resonance ...
Antria Filippou   +4 more
doaj   +1 more source

Elucidating the Phantom Phantom

open access: yesHypothesis, 2008
Research magnetic resonance imaging (MRI) faces the negative effects of the phantom phantom, a spirit that haunts the MRI system, specifcally targeting inanimate "phantoms" used for imaging in the absence of a willing human. The detrimental effects of the phantom phantom are strongest when frustration is high. Here, given appropriate frustration, it is
openaire   +1 more source

Home - About - Disclaimer - Privacy