Teager energy based dynamic phasor estimation
2012 Annual IEEE India Conference (INDICON), 2012The ability of Phasor Measurement Units to measure the phase angle of input signals makes them suitable for dynamic events monitoring. However, under dynamic conditions, e.g., power swing, the steady state definition of the synchrophasors is no more valid and the measurement accuracy is inevitably lower.
Ranjana Sodhi, S C Srivastava, S N Singh
openaire +1 more source
A Novel Distribution-Level Phasor Estimation Algorithm Using Empirical Wavelet Transform
IEEE transactions on industrial electronics (1982. Print), 2018Distribution-level signals are often contaminated with harmonics and noise, along with dynamic conditions like frequency deviations. This paper proposes an empirical wavelet transform (EWT) based M-class distribution-level phasor estimation technique ...
Kapil Chauhan +2 more
semanticscholar +1 more source
Dynamic Harmonic Phasor Estimator Considering Frequency Deviation
IEEE Sensors Journal, 2021The fundamental frequency of power system may deviate from the nominal value due to various reasons, such as load variation, subsynchronous resonance and fault occurrence. The maximum frequency deviation considered by the latest IEEE standard is 5 Hz.
Wenfan Li +4 more
openaire +1 more source
IEEE Power & Energy Society General Meeting, 2019
During transmission line faults, a sampled current signal can contain two decaying dc components (DDCs). A primary DDC develops on the faulted transmission line and a secondary DDC arises at a current transformer of the numerical relay.
J. Hwang
semanticscholar +1 more source
During transmission line faults, a sampled current signal can contain two decaying dc components (DDCs). A primary DDC develops on the faulted transmission line and a secondary DDC arises at a current transformer of the numerical relay.
J. Hwang
semanticscholar +1 more source
DFT-Based Phasor Estimation for Removal of the Effect of Multiple DC Components
IEEE Transactions on Power Delivery, 2018A current sampled signal in a faulted transmission line can contain multiple dc components, namely a primary decaying dc component (DDC), a secondary DDC, an auxiliary DDC, and a bias DDC, and these may be due to a faulted line, current transformer ...
J. Hwang, C. Song, M. Jeong
semanticscholar +1 more source
Development of Dictionary-Based Phasor Estimator Suitable for P-Class Phasor Measurement Unit
IEEE Transactions on Instrumentation and Measurement, 2018The paper proposes a simple phasor estimator by utilizing the dictionary-based sparse representation of signals for control and protection applications in power system. It is also observed that the proposed method is found to be suitable for extracting the fundamental component of the signal required for protective relays with few number of samples ...
Shaik Affijulla, Praveen Tripathy
openaire +1 more source
A Teaching Tool for Phasor Measurement Estimation
IEEE Transactions on Power Systems, 2014This paper discusses the design and usage of a Simulink-based phasor measurement unit (PMU) simulator package. The simulator and PMU data is available upon request from the first author. The motivation for developing the package is to provide a flexible environment for teaching phasor measurement and frequency estimation to advanced undergraduate and ...
Daniel Dotta +2 more
openaire +1 more source
Diakoptic State Estimation Using Phasor Measurement Units
IEEE Transactions on Power Systems, 2008This paper presents a diakoptic-based distributed state estimation (SE) algorithm suitable for large-scale power systems. In the proposed approach the large-scale power system is divided into a certain number of subsystems by removing tie line measurements. Based on diakoptic theory, the SE problem is then partitioned into a number of subproblems which
null Weiqing Jiang +2 more
openaire +1 more source
Recursive phasor estimation algorithm for synchrophasor measurement
2015 IEEE International Workshop on Applied Measurements for Power Systems (AMPS), 2015One of the enabling technologies for smart grid development are synchrophasor measurements typically performed by devices called phasor measurement unit (PMU), that produce synchronized subsecond high-resolution voltage and current measurements, so greatly augment the traditional response time of supervisory control and data acquisition measurements ...
Cuccaro, Pasquale +4 more
openaire +2 more sources
Two stage state estimator with phasor measurements
2009 International Conference on Power Systems, 2009State estimator is an important tool for online monitoring, analysis and control of power systems. With the increased use of phasor measurement units in a power grid, utilization of synchro phasor measurements in State Estimation (SE) becomes essential.
K. Jamuna, K.S. Swarup
openaire +1 more source