Results 21 to 30 of about 11,034 (258)
Photon-counting detector CT: early clinical experience review
Since its development in the 1970s, X-ray CT has emerged as a landmark diagnostic imaging modality of modern medicine. Technological advances have been crucial to the success of CT imaging, as they have increasingly enabled improvements in image quality and diagnostic value at increasing radiation dose efficiency.
Sartoretti, Thomas +3 more
openaire +2 more sources
Spectral X-Ray CT Image Reconstruction with a Combination of Energy-Integrating and Photon-Counting Detectors. [PDF]
The purpose of this paper is to develop an algorithm for hybrid spectral computed tomography (CT) which combines energy-integrating and photon-counting detectors.
Qingsong Yang +3 more
doaj +1 more source
An introduction to photon-counting detector CT (PCD CT) for radiologists
AbstractThe basic performance of photon-counting detector computed tomography (PCD CT) is superior to conventional CT (energy-integrating detector CT: EID CT) because its spatial- and contrast resolution of soft tissues is higher, and artifacts are reduced.
Yuko Nakamura +5 more
openaire +2 more sources
To compare the performance of energy-integrating detector (EID) CT, photon-counting detector CT (PCCT), and high-resolution PCCT (HR-PCCT) for the visualization of coronary plaques and reduction of stent artifacts in a phantom model.An investigational scanner with EID and PCCT subsystems was used to image a coronary artery phantom containing ...
Jayasai R. Rajagopal +12 more
openaire +3 more sources
Advanced Imaging of Shunt Valves in Cranial CT Scans with Photon-Counting Scanner
This brief report aimed to show the utility of photon-counting technology alongside standard cranial imaging protocols for visualizing shunt valves in a patient’s cranial computed tomography scan.
Anna Klempka +4 more
doaj +1 more source
Ring-artifacts removal for photon-counting CT
Ring artifacts usually appear in photon counting computed tomography (PCCT) images, which may compromise image quality and cause non-uniformity bias. This study proposed a fast ring artifacts removal method by exploring the correlation from projections with different views for PCCT. This method has three advantages.
Kang An +4 more
openaire +2 more sources
Photon-counting CT for forensic death investigations—a glance into the future of virtual autopsy
This article explores the potential of photon-counting computed tomography (CT) in forensic medicine for a range of forensic applications. Photon-counting CT surpasses conventional CT in several key areas.
Dominic Gascho
doaj +1 more source
Clinical applications of photon-counting CT in neuroimaging [PDF]
Photon-counting computed tomography (PCCT) is a next-generation CT imaging technology that markedly improves image quality while reducing radiation dose and image noise through single-photon detection and energy discrimination by photon detectors.
LÜ Haiying, LU Yong, HE Naying
doaj +1 more source
The two-parameter-fitting method (PFM) is commonly used to calculate the stopping-power ratio (SPR). This study proposes a new formalism: a three-PFM, which can be used in multiple spectral computed tomography (CT).
Sung Hyun Lee +8 more
doaj +1 more source
Background With the emergence of photon-counting CT, ultrahigh-resolution (UHR) imaging can be performed without dose penalty. This study aims to directly compare the image quality of UHR and standard resolution (SR) scan mode in femoral artery ...
Philipp Gruschwitz +12 more
doaj +1 more source

