Results 11 to 20 of about 673,488 (182)
Undulator A diagnostics at the Advanced Photon Source [PDF]
Diagnostics of Undulator A{number_sign}2 (UA2) radiation was performed during the October 1997 mn at the Advanced Photon Source (APS). The UA2 undulator is a standard 3.3-cm-period APS Undulator A, which was positioned downstream from the center of the straight section at Sector 8.
Ilinski, P.
openaire +4 more sources
Photon acceleration versus frequency-domain interferometry for laser wakefield diagnostics
A detailed comparison between photon acceleration and frequency-domain interferometry, for laser wakefield diagnostics, is presented here. The dispersion effects on the probe beam and the implications of an arbitrary phase velocity of the plasma wave are
J. M. Dias +2 more
doaj +2 more sources
Photon Diagnostics and Photon Beamlines Installations at the European XFEL
Proceedings of the 37th International Free Electron Laser Conference, FEL2015, Daejeon, Republic of ...
Grünert, Jan +11 more
core +4 more sources
Photon diagnostics at the FLASH THz beamline. [PDF]
The THz beamline at FLASH, DESY, provides both tunable (1–300 THz) narrow-bandwidth (∼10%) and broad-bandwidth intense (up to 150 uJ) THz pulses delivered in 1 MHz bursts and naturally synchronized with free-electron laser X-ray pulses. Combination of these pulses, along with the auxiliary NIR and VIS ultrashort lasers, supports a plethora of dynamic ...
Pan R +17 more
europepmc +9 more sources
SwissFEL Aramis beamline photon diagnostics. Erratum. [PDF]
The list of authors in the paper by Juranić et al. (2018) [J. Synchrotron Rad. 25, 1238–1248] is corrected.
Juranić P +21 more
europepmc +4 more sources
Influence of refractive index matching on the photon diffuse reflectance [PDF]
Photon migration in a randomly inhomogeneous, highly scattering and absorbing semi-infinitemediumwith a plane boundary is considered by aMonte Carlo (MC) technique. The employed MC technique combines the statistical weight scheme and real photon paths
Churmakov, D. Y. +2 more
core +7 more sources
FLASH2: Operation, beamlines, and photon diagnostics [PDF]
FLASH2, a major extension of the soft X-ray free-electron laser FLASH at DESY, turns FLASH into a multi-user FEL facility. A new undulator line is located in a separate accelerator tunnel and driven additionally by the FLASH linear accelerator. First lasing of FLASH2 was achieved in August 2014 with simultaneous user operation at FLASH1. The new FLASH2
Plönjes, Elke +3 more
openaire +2 more sources
Robotic thoracoscopic parathyroidectomy for ectopic mediastinal parathyroid adenoma
The publication presents the successful experience of using the DaVinci robotic system for the treatment of persistent hyperparathyroidism caused by mediastinal ectopic parathyroid adenoma in 62 years old female patient.
P. K. Yablonsky +4 more
doaj +1 more source
Biomedical Photonics Methods in Solving Diagnostic Tasks
Modern photonics methods are considered in relation to solving a number of diagnostic problems in practical medicine. The basic principles of the application of optical noninvasive diagnostic methods are described and examples are given: laser Doppler flowmetry, digital diaphanoscopy, Raman spectroscopy, spectrophotometry, time-resolved fluorescence ...
Dunaev, A. V. +5 more
openaire +2 more sources
State-of-the-Art Research: Current Developments in CT Imaging
This Special Issue of Diagnostics entitled “Advances in CT Images” provides an interesting selection of articles on recent technical developments in CT imaging with a special focus on spectral imaging, including dual-energy CT (DECT) and photon-counting ...
Christian Booz
doaj +1 more source

