Smart Closed‐Loop Systems in Personalized Healthcare: Advances and Outlook
A smart closed‐loop e‐textile integrates multimodal sensing, onboard processing, wireless communication, and wearable power to enable real‐time physiological/biochemical monitoring and feedback‐controlled therapy. ABSTRACT Smart textiles represent a revolutionary frontier in healthcare, seamlessly blending fabric and advanced technologies to create ...
Safoora Khosravi +12 more
wiley +1 more source
Re-weighted estimation of the transition probability density for second-order diffusion processes. [PDF]
Li Y, Wang Y, Tang M.
europepmc +1 more source
A custom shape memory polymer material selection process relates quantitative application criteria (e.g., compression garment yarns) to material characterization information. The selected materials are manufactured into yarn geometries, which expand the design space by creating structural stress‐strain profiles beyond the nominal material stress‐strain
Michaela Andrews +2 more
wiley +1 more source
O-RAID: a satellite constellation architecture for ultra-resilient global data backup. [PDF]
Meegama RGN.
europepmc +1 more source
Framework educational programme for basic education (with amendments as at 1. 9. 2007) [PDF]
Je\u159\ue1bek, Jaroslav, Tup\ufd, Jan
core
A Pressure Microsensor Made of Parylene‐C for Use as Medical Implant
A monolithic parylene‐C pressure sensor with gold strain gauges provides 6.2 μV$\mu{\rm V}$·mmHg$\cdot{\rm mmHg}$−1$^{-1}$ sensitivity. The morphology of a sputtered thin film strain sensor is granular/columnar, which results in a high gauge factor of 7.5. Thermal bonding and parylene‐C coating create a hermetic cavity.
Ann‐Kathrin Klein +2 more
wiley +1 more source
Probing Photoluminescence in Perovskite-Based Polymer Nanocomposite Films. [PDF]
Renaud JF +8 more
europepmc +1 more source
ABSTRACT Quantifying oral polymorphonuclear neutrophils (oPMNs) is a clinically validated approach for assessing periodontal inflammation. However, current methods, such as manual hemocytometry and flow cytometry, are time‐consuming (>3 h), require invasive sampling, and depend on staining and complex instrumentation, making them unsuitable for point ...
Mohsen Hassani +9 more
wiley +1 more source
Synthetic Mimics for Nitrogen-Based Polycyclic Aromatic Hydrocarbon Cosmic Dust: Preparation and Preliminary Impact Ionization Mass Spectrometry Studies. [PDF]
Zeng M +5 more
europepmc +1 more source
Multimodal Haptic Perception Through Synergistic Nanocomposite Sensor Arrays
Multi‐modal fingertip haptics are advanced through a bioinspired &vertical‐via' electronic skin architecture. A confined PDMS/MWCNT/NiNP nanocomposite, sitting at the percolation threshold, enables tactile, thermal, and magnetic sensing. A unique via‐density gradient and dedicated &Un‐Touch' reference nodes provide robust spatial resolution and signal ...
Amos Bardea, Fernando Patolsky
wiley +1 more source

