Results 171 to 180 of about 4,777 (211)
Some of the next articles are maybe not open access.

Directional factors of radially polarized piezoceramic cylindrical transducers

The Journal of the Acoustical Society of America, 2021
An experimental investigation on the directional factors of radially polarized piezoceramic cylindrical transducers as a function of aspect ratio and for different design boundary conditions (fluid-filled, air-backed, and open-closed squirter) is presented.
Michael St. Pierre   +2 more
openaire   +1 more source

Multiple piezoceramic transducers (PZT)-structure interaction model

SPIE Proceedings, 2006
Piezoceramic (PZT) transducers are extensively used for damage detection in electromechanical impedance (EMI) based structural health monitoring (SHM) of engineering systems. In the EMI methods, the PZT transducers are generally surface bonded or embedded inside the host structure, and then subjected to actuation so as to interrogate the structure for ...
Venu G. M. Annamdas, Chee K. Soh
openaire   +1 more source

["Pulse" piezoceramic transducer].

Meditsinskaia tekhnika, 1978
A piezoceramic acceleration sensor "Pulse", devised by the Gorky Scientific-Research Radiphysical Institute is described. The use in the sensor's design of a flexing sensitive element provides for high sensitivity and great power output of the instrument. This helps to easily coordinate the operation of the sensor with that of the recording devices and
N M, Anishkina   +3 more
openaire   +1 more source

Flexural waves transmitted by rectangular piezoceramic transducers

Smart Materials and Structures, 2001
Rectangular piezoceramic transducers are widely used in ultrasonic evaluation and health monitoring techniques and structural vibration control applications. In this paper the flexural waves excited by rectangular transducers adhesively attached to isotropic plates are investigated.
Veidt, Martin   +2 more
openaire   +2 more sources

Calculation of harmonically driven piezoceramic transducers

Measurement Techniques, 1994
The electric field E in a poled dielectric is calculated numerically taking into account its electrical conductivity as a function of the driving frequency and the dielectric relaxation time. The conditions are determined for E to be independent of the driving frequency, stabilizing the characteristics of the transducers.
openaire   +1 more source

Concrete structural health monitoring using embedded piezoceramic transducers

Smart Materials and Structures, 2007
Health monitoring of reinforced concrete bridges and other large-scale civil infrastructures has received considerable attention in recent years. However, traditional inspection methods (x-ray, C-scan, etc) are expensive and sometimes ineffective for large-scale structures. Piezoceramic transducers have emerged as new tools for the health monitoring of
G Song   +4 more
openaire   +1 more source

Acoustic Remote Sensing Piezoceramic Transducers with Internal Screen

2020 IEEE 40th International Conference on Electronics and Nanotechnology (ELNANO), 2020
The analytical relationships, allowing to quantify the parameters of the cylindrical piezoceramic transducers with internal screens for remote sensing acoustic fields by means of the related fields method in multiply assessments of the resonance radiation spectra and the angular distribution features of acoustic fields at the resonant frequencies ...
Oleksandr Leiko   +3 more
openaire   +1 more source

Active vibration control using shear mode piezoceramic transducers

The Journal of the Acoustical Society of America, 1991
The “d15 ” constant of the piezoceramics was utilized to design shear mode transducers. These shear mode transducers were verified to be pure shear stress/strain sensors/actuators both theoretically and numerically (ANSYS). Active torsional vibration control experiments were conducted on various phenolic and pyrex tubes by using the shear mode sensors ...
Chia-Chi Sung   +3 more
openaire   +1 more source

Calculation of nonuniformly thickness-polarized piezoceramic transducers

Measurement Techniques, 1995
Equations are given for calculating mechanical stress as a function of strain and electric field. The method described for calculating the bending deflection of the free end of a cantilevered, homogeneous, piezoceramic wafer can be used to determine the true polarization distribution created in the fabrication of piezoelectric transducers.
openaire   +1 more source

Micro-Stereolithography of KNN Piezoceramics for Ultrasonic Transducers

2018 IEEE International Ultrasonics Symposium (IUS), 2018
As a noninvasive, cost-effectiveness, and real-time imaging technology, ultrasonic imaging has been successfully applied in medical diagnostic and therapeutic applications. However, the design and fabrication of ultrasonic transducers, the core component of ultrasonic imaging system, greatly limit its applications and development.
Weicen Chen   +3 more
openaire   +1 more source

Home - About - Disclaimer - Privacy