Results 31 to 40 of about 3,247,114 (269)
Effects of corrosion on bearing capacity of steel pile foundation in acidic soil
Soil acidity is one of the reasons for corrosion of steel piles. The material deterioration of steel pile foundation served in the acidic soil will affect the safety and durability of pile foundation.
WANG Feng-chi , GAO Huan , FENG Xu-ning , LIU Tian-tian
doaj +1 more source
Application of Artificial Neural Network for Predicting Shaft and Tip Resistances of Concrete Piles
<p class="MsoNormal" style="text-align: justify; line-height: 200%;">Axial bearing capacity (ABC) of piles is usually determined by static load test (SLT). However, conducting SLT is costly and time-consuming. High strain dynamic pile testing (HSDPT) which is provided by pile driving analyzer (PDA) is a more recent approach for predicting the ABC
Momeni, Ehsan +3 more
openaire +4 more sources
Development Bearing Capacity of Piles Embedded in Clayey Soil [PDF]
The load carrying capacity of piles resulting from base resistance and shaft resistance, the load transfer mechanism of piles is complicated since the mode of failure of these components is different in addition to the effect of pile installation on the ...
Awf Al-Kaisi +2 more
doaj +1 more source
The impact of leukocyte‐associated RNA retention on platelet RNA‐based cancer detection
Platelets carry RNA signals that may help detect cancer, but platelet samples can also retain RNA from white blood cells. We found that this retained white blood cell signal did not significantly affect machine learning cancer classification, suggesting that the cancer‐related RNA signal in platelets is largely independent of leukocyte‐associated RNA ...
Michał Sieczczyński +12 more
wiley +1 more source
In the layered soil foundation mainly composed of silty clay and silty clay, test piles with full cross-section pressure sensors installed at the end of piles are used to continuously and intensively collect pile tip resistances in the whole penetrating ...
Sang, SK +4 more
core +1 more source
Miniaturized flow chip platform enabling continuous perfusion and longitudinal multiphoton 3D imaging of vascular smooth muscle cell constructs under physiological flow. Brightfield imaging guides region selection, while CellTracker Green and mRuby‐labeled fetuin‐A visualize cells and mineral deposition, respectively. Magnesium supplementation markedly
Vytautas Kučikas +6 more
wiley +1 more source
The thermal behaviour of three different auger pressure grouted piles used as heat exchangers [PDF]
Three auger pressure grouted (APG) test piles were constructed at a site in Richmond, Texas. The piles were each equipped with two U-loops of heat transfer pipes so that they could function as pile heat exchangers.
Brettmann, T +11 more
core +1 more source
ABSTRACT Objective The prognosis of glioblastoma (GBM) remains highly unfavorable, largely due to high tumor heterogeneity and an immunosuppressive microenvironment. However, the functional role of PANoptosis in this context is poorly understood. Methods Patients were stratified via K‐means clustering. A risk score model was constructed using prognosis‐
Langfei Tian +6 more
wiley +1 more source
Calculation of bearing capacity for combined post-grouting bored piles based on settlement control
It is of great practical significance to determine the bearing capacity of post-grouting piles on the basis of the principle of settlement control. Based on the field static load tests on six large-diameter cast-in-situ bored piles of Shishou Yangtze ...
DAI Guo-liang 1,2, WAN Zhi-hui 1,2, , GONG Wei-ming 1,2, WANG Lei 3
doaj +1 more source
Method for Calculating Vertical Compression Bearing Capacity of the Static Drill Rooted Nodular Pile
The static drill rooted nodular (SDRN) pile is a new kind of composite pile foundation made by inserting a precast nodular pile into the cemented soil.
Jing Guo, Guoliang Dai, Yue Wang
doaj +1 more source

