Results 181 to 190 of about 11,694 (225)
Some of the next articles are maybe not open access.
A rapid PMU-based load composition and PMU estimation method
Electric Power Systems Research, 2017Abstract Advanced protection and operation of power systems, especially microgrids, requires rapid detection and estimation of system states. Microgrids, however, are a challenge due to the high variability of distributed generation and modern load profiles.
Benjamin McCamish +9 more
openaire +1 more source
2016
Instrument transformers (ITs) are key elements in any measurement system and, in particular, their role is fundamental in applications such as PMUs, where the requirements on the measurement uncertainty are very strict. The characteristics, in terms of accuracy, electrical insulation, and mechanical property, that must be fulfilled by ITs employed in ...
PERETTO, LORENZO, TINARELLI, ROBERTO
openaire +2 more sources
Instrument transformers (ITs) are key elements in any measurement system and, in particular, their role is fundamental in applications such as PMUs, where the requirements on the measurement uncertainty are very strict. The characteristics, in terms of accuracy, electrical insulation, and mechanical property, that must be fulfilled by ITs employed in ...
PERETTO, LORENZO, TINARELLI, ROBERTO
openaire +2 more sources
Software platform for PMU algorithms testing
2012 Conference on Precision electromagnetic Measurements, 2012This paper describes a software platform used for the testing of PMU algorithms. The platform is implemented in MATLAB and consists of two parts. The first one permits the insertion of the simulation parameters while the second is the actual simulator for the algorithms.
Umberto Pogliano +3 more
openaire +2 more sources
22nd International Conference and Exhibition on Electricity Distribution (CIRED 2013), 2013
The PMU (Phasor Measurement Unit) is used for accurate measurement of synchronous phasor of voltages and currents. Based on synchronous phasor continuous measurement at the different location of distribution network is possible prevent fault which can cause blackout. Synchronous phasor measurement is described in IEEE C37.118-2005 standard.
M. Horinek, P. Bilik, T. Wittassek
openaire +1 more source
The PMU (Phasor Measurement Unit) is used for accurate measurement of synchronous phasor of voltages and currents. Based on synchronous phasor continuous measurement at the different location of distribution network is possible prevent fault which can cause blackout. Synchronous phasor measurement is described in IEEE C37.118-2005 standard.
M. Horinek, P. Bilik, T. Wittassek
openaire +1 more source
The PMU performance evaluation
2012 Conference on Precision electromagnetic Measurements, 2012In this paper, the PMU performances evaluation, especially the dynamic one, are presented, which is significant for improving PMU behavior in smart grid. The comprehensive test program including steady state test and dynamic test is outlined. And the details of the test items are revealed.
Hao Liu, Tianshu Bi, Qixun Yang
openaire +1 more source
International Journal of Emerging Electric Power Systems, 2010
This paper details the main requirements that must be taken into account to assemble a phasor unit measurement (PMU) for research and educational purposes. The device's main elements are described showing their interrelationship. Likewise, details about the most important functions are exposed.
Blanca V. Hernandez +3 more
openaire +1 more source
This paper details the main requirements that must be taken into account to assemble a phasor unit measurement (PMU) for research and educational purposes. The device's main elements are described showing their interrelationship. Likewise, details about the most important functions are exposed.
Blanca V. Hernandez +3 more
openaire +1 more source
2018 Conference on Precision Electromagnetic Measurements (CPEM 2018), 2018
There is a need for traceable calibrations of Phasor measurement units, which measures the phase angle of power system signals with respect to the universal time. This paper describes the design of such a calibration system. The system utilizes a fast A-D converter, synchronized to the Swedish time and frequency realization.
Stefan Svensson +3 more
openaire +1 more source
There is a need for traceable calibrations of Phasor measurement units, which measures the phase angle of power system signals with respect to the universal time. This paper describes the design of such a calibration system. The system utilizes a fast A-D converter, synchronized to the Swedish time and frequency realization.
Stefan Svensson +3 more
openaire +1 more source
2018 Clemson University Power Systems Conference (PSC), 2018
Phasor Measurement Units (PMUs) have been used for several years to record information on power system, especially in transmission system. Their ability to synchronize to Global Positioning System (GPS) time, enables them to make accurate measurements of angle differences.
Lung-An Lee, Virgilio Centeno
openaire +1 more source
Phasor Measurement Units (PMUs) have been used for several years to record information on power system, especially in transmission system. Their ability to synchronize to Global Positioning System (GPS) time, enables them to make accurate measurements of angle differences.
Lung-An Lee, Virgilio Centeno
openaire +1 more source
Efficient Compression of PMU Data in WAMS
IEEE Transactions on Smart Grid, 2016Widespread placement and high data sampling rate of current generation of phasor measurement units (PMUs) in wide area monitoring systems result in huge amount of data to be analyzed and stored, making efficient storage of such data a priority. This paper presents a generalized compression technique that utilizes the inherent correlation within PMU ...
Phani Harsha Gadde +3 more
openaire +2 more sources
Optimal pmu placement for distribution networks
2017 IEEE Innovative Smart Grid Technologies - Asia (ISGT-Asia), 2017This paper presents the optimal phasor measurement (PMU) placement for distribution networks. The optimal PMU placement (OPP) formulation from related literatures is presented in integer linear programming (ILP) framework where zero injection buses (ZIBs), PMU channel limitation, PMU outages and line outages were considered.
Abdul Aziz G. Mabaning +2 more
openaire +2 more sources

