Results 161 to 170 of about 9,722 (191)
Some of the next articles are maybe not open access.

A rapid PMU-based load composition and PMU estimation method

Electric Power Systems Research, 2017
Abstract Advanced protection and operation of power systems, especially microgrids, requires rapid detection and estimation of system states. Microgrids, however, are a challenge due to the high variability of distributed generation and modern load profiles.
Benjamin McCamish   +9 more
openaire   +1 more source

Verifying interoperability and application performance of PMUs and PMU-enabled IEDs

2012 IEEE Power and Energy Society General Meeting, 2012
This paper presents a new test methodology for verifying the interoperability and application performance of PMUs and PMU-enabled IEDs at the device and system level. Two types of tests are defined to evaluate the performance of synchrophasor devices from two different aspects: design and application.
J. Ren, M. Kezunovic, Y. Guan
openaire   +1 more source

The PMU dynamic performance evaluation and the comparison of PMU standards

2012 IEEE Power and Energy Society General Meeting, 2012
Synchronized phasor measurement is one of the most important information sources for smart transmission grid, which provides a new path for power system dynamic monitoring, analysis and control. Therefore whether the PMU (phasor measurement unit) can track the status of the power system, especially under the dynamic condition, is crucial.
null Tianshu Bi   +3 more
openaire   +1 more source

Sensors for PMUs

2016
Instrument transformers (ITs) are key elements in any measurement system and, in particular, their role is fundamental in applications such as PMUs, where the requirements on the measurement uncertainty are very strict. The characteristics, in terms of accuracy, electrical insulation, and mechanical property, that must be fulfilled by ITs employed in ...
PERETTO, LORENZO, TINARELLI, ROBERTO
openaire   +2 more sources

PMU standard of China

APCCAS 2008 - 2008 IEEE Asia Pacific Conference on Circuits and Systems, 2008
At the end of 2006, Chinese WAMS/GPS working group has started the renewal of PMU standards. Synchrophasor measurement, dynamic recording and real-time communication are defined as primary functions of PMU. Working group suggest PMU shall measure generator rotor angle.
null Jingtao Wu   +4 more
openaire   +1 more source

The PMU performance evaluation

2012 Conference on Precision electromagnetic Measurements, 2012
In this paper, the PMU performances evaluation, especially the dynamic one, are presented, which is significant for improving PMU behavior in smart grid. The comprehensive test program including steady state test and dynamic test is outlined. And the details of the test items are revealed.
Hao Liu, Tianshu Bi, Qixun Yang
openaire   +1 more source

“Frequency” and the PMU standard

2021 IEEE International Instrumentation and Measurement Technology Conference (I2MTC), 2021
The Phasor Measurement Unit (PMU) has revolutionized power system management by providing high-resolution, time-stamped, spatial, and temporal measurements of the state of power systems. However, the standards defining the measured quantities have ambiguities that cause uncertainty, irreproducibility, and loss of interoperability during periods of ...
A. Riepnieks   +3 more
openaire   +1 more source

A PMU Calibration System

2018 Conference on Precision Electromagnetic Measurements (CPEM 2018), 2018
There is a need for traceable calibrations of Phasor measurement units, which measures the phase angle of power system signals with respect to the universal time. This paper describes the design of such a calibration system. The system utilizes a fast A-D converter, synchronized to the Swedish time and frequency realization.
Stefan Svensson   +3 more
openaire   +1 more source

Software platform for PMU algorithms testing

2012 Conference on Precision electromagnetic Measurements, 2012
This paper describes a software platform used for the testing of PMU algorithms. The platform is implemented in MATLAB and consists of two parts. The first one permits the insertion of the simulation parameters while the second is the actual simulator for the algorithms.
Umberto Pogliano   +3 more
openaire   +1 more source

Optimal placement of PMUs & analytics on PMU data using ANN technique

2017 International Conference on Energy, Communication, Data Analytics and Soft Computing (ICECDS), 2017
Power system play a vital role in human life. The reliability of these power systems depends on the operating constraints & conditions. PMU (Phasor measurement units) utilizes synchronization signals provided by the GPS (global positioning system) satellites and deliver the voltage and currents phasors measured at a given node.
R Kiran   +2 more
openaire   +1 more source

Home - About - Disclaimer - Privacy