Results 91 to 100 of about 14,040 (210)
Overall Complications • Early cranioplasty showed a higher (but non‐significant) risk • RR 1.43 (95% CI: 0.81–2.53) • Heterogeneity: I2 = 57% Post‐operative Infection • Early cranioplasty associated with a non‐significant increase • RR 1.36 (95% CI: 0.36–5.11) • Heterogeneity: I2 = 38% Operative Time • Early cranioplasty resulted in a significantly ...
Muhammad Taha +21 more
wiley +1 more source
Nanostructuring polyetheretherketone for medical implants [PDF]
Surface roughness is a vital factor for medical implants since the cells of the surrounding tissue interact with the underlying substrate on the micro- and nanometer scales.
Althaus, Jasmin +5 more
core
Specific heat capacity and thermal conductivity of PEEK/Ag nanoparticles composites determined by Modulated-Temperature Differential Scanning Calorimetry [PDF]
The thermal conductivity accurate measurement of polymer based composites is a challenge: it would allow us to understand the mechanisms of thermal transport in such materials. Silver nanoparticles were introduced in Polyetheretherketone matrix and their
Caussé, Nicolas +4 more
core +3 more sources
Rheological Properties of Polyether Ether Ketones Containing Multi‐Walled Carbon Nanotubes
Rheology, Melt Flow, and Spinnability of PEEK‐MWCNT Melts After Compounding. ABSTRACT In this study, the rheological and melt‐flow behavior of polyether ether ketone (PEEK) filled with multi‐walled carbon nanotubes (MWCNTs) was investigated to evaluate its melt‐spinnability.
Toty Onggar, Chokri Cherif
wiley +1 more source
Continuous fiber thermoplastic prepreg [PDF]
A pultrusion machine employing a corrugated impregnator vessel to immerse multiple, continuous strand, fiber tow in an impregnating material, and an adjustable metered exit orifice for the impregnator vessel to control the quantity of impregnating ...
Johnson, Gary S., Wilson, Maywood L.
core +1 more source
MRI‐derived bone quality metrics are reliable predictors of cage subsidence following ACDF. Their implementation may be used to guide surgical planning and improve outcomes. ABSTRACT Objective Cage subsidence following anterior cervical discectomy and fusion (ACDF) is linked with poor bone quality.
Omar Lubbad +8 more
wiley +1 more source
Biological tribological properties between polyetheretherketone and patella cartilage
Reciprocating sliding friction and wear tests were carried out on polyetheretherketone (PEEK) and natural patella cartilage using the pin-on-disk configuration at different normal loads, slipping velocity and friction pairs under 25% fetal bovine serum ...
ZHANG Xin-yue +3 more
doaj +1 more source
Augmenting the bioactivity of polyetheretherketone
Background Polyetheretherketone (PEEK) may be advantageous as an alternative material to metal alloys in some orthopaedic applications. However, it is bioinert and does not osseointegrate1. A novel accelerated neutral atom beam technique (ANAB) has been developed to improve the bioactivity of PEEK where the surface is modified to a depth of 5 nm ...
Sara, Ajami +3 more
openaire +1 more source
Feasibility study of fusion bonding for carbon fabric reinforced Polyphenylene Sulphide by hot-tool welding [PDF]
In recent years, there is a growing interest in joining techniques for thermoplastic composites as an alternative to adhesive bonding. In this article, a fusion bonding process called hot-tool welding is investigated for this purpose and the used ...
De Baere, Ives +2 more
core +1 more source
A covalent organic/inorganic hybrid proton exchange polymeric membrane: synthesis and characterization [PDF]
Commercial polyetheretherketone (Victrex PEEK) was sulfonated up to 90% degree of sulfonation (DS), then reacted with SiCl4 to obtain a hybrid polymer. The product was characterized by 29-Si NMR and ATR/FTIR spectroscopies demonstrating the formation of
D'Epifanio, A +5 more
core +1 more source