Results 81 to 90 of about 379,451 (283)
Real‐Time 3D Ultrasound Imaging with an Ultra‐Sparse, Low Power Architecture
This article presents a novel, ultra‐sparse ultrasound architecture that paves the way for wearable real‐time 3D imaging. By integrating a unique convolutional array with chirped data acquisition, the system achieves high‐resolution volumetric scans at a fraction of the power and hardware complexity.
Colin Marcus +9 more
wiley +1 more source
Although the entropy algorithm is widely applied in signal complexity analysis, its stability and reliability are limited due to the existence of abnormal signal points.
Hairong Yu, Yuanyu Wu, Rong Song
doaj +1 more source
A Simple Imaging Device for Fluorescence-Relevant Applications
This article unveiled the development of an inexpensive, lightweight, easy-to-use, and portable fluorescence imaging device for paper-based analytical applications.
Shih-Jie Lo +6 more
doaj +1 more source
Backpack VLBI terminal with subscentimeter capability [PDF]
Backpack portable equipment was developed to measure vector baseline from approximately 1 km to 100 km in length with subcentimeter to few centimeter accuracy. The equipment design features as well as the instrumentation specifications are discussed.
Connselman, C. C., III +3 more
core +1 more source
xx xx. ABSTRACT Stimuli‐responsive nanomaterials capable of spatiotemporal control over drug release are of nanocomposite patch (“e‐Medi‐Patch”) engineered from biodegradable polycaprolactone (PCL), graphene nanoplatelets, and a redox‐active therapeutic, niclosamide. The hierarchical composite integrates π‐π interactions between aromatic drug molecules
Santosh K. Misra +7 more
wiley +1 more source
A portable, low-cost flight-data measurement and recording system [PDF]
The design of and the experience with an inexpensive, hand-portable, onboard data system used to record four parameters in the final portion of the landing approach and touchdown of an airplane are described. The system utilized a high-quality audio tape
Miller, R. J.
core +1 more source
A high‐capacity polyimide‐linked porous organic polymer (HAT‐PTO) incorporating numerous redox‐active centers is synthesized via a hydrothermal reaction, delivering a high theoretical capacity of 484 mAh g−1. In situ hybridization with carboxyl‐functionalized multiwalled carbon nanotubes enhances conductivity and stability, achieving 397 mAh g−1 at C ...
Arindam Mal +7 more
wiley +1 more source
PERANCANGAN DAN PEMBUATAN ALAT KERAMAS PORTABLE UNTUK PASIEN RUMAH SAKIT DENGAN METODE MORFOLOGI
Kenyamanan dan perawatan diri merupakan kebutuhan dasar manusia baik dalam keadaan sehat maupun dalam kondisi sedang dirawat. Makalah ini bertujuan mengembangkan alat keramas portable untuk pasien rumah sakit.
Jamari Jamari, A.V. Yolanda
doaj +1 more source
Standards for material handling and facilities equipment proofload testing [PDF]
Document provides information on verifying the safety of material handling and facilities equipment /MH/FE/, ranging from monorail systems to ladders and non-powered mobile equipment.
Bonn, S. P.
core +1 more source
Electrically Readable Lateral Flow Assay Using Organic Transistors for Diagnostic Applications
Electrolyte‐gated organic field‐effect transistors (EGOFETs) are integrated with lateral flow (LF) paper fluidics to create a reusable, portable, and low‐cost point‐of‐care (PoC) diagnostic test. The devices are validated for Human Immunoglobulin G detection, achieving high sensitivity (0.1 fm), selectivity, and reproducibility with rapid results in 20–
María Jesús Ortiz‐Aguayo +4 more
wiley +1 more source

