Results 1 to 10 of about 715,988 (153)

Efficacy and safety of primary posterior capsulotomy during phaco-vitrectomy for epiretinal membrane [PDF]

open access: yesBMC Ophthalmology, 2022
Purpose To evaluate the necessity and safety of primary posterior capsulotomy during phaco-vitrectomy for idiopathic epiretinal membrane (ERM). Setting Seoul National University Bundang Hospital, Seongnam, Korea.
Ki Won Jin, Se Joon Woo, Kyu Hyung Park
doaj   +3 more sources

Perception of difficulties with vision-related activities of daily living among patients undergoing unilateral posterior capsulotomy [PDF]

open access: yesClinics, 2010
OBJECTIVES: To assess the influence of Nd:YAG (neodymium: yttrium-aluminum- garnet) laser unilateral posterior capsulotomy on visual acuity and patients' perception of difficulties with vision-related activities of daily life.
Firmani M. B. de Senne   +3 more
doaj   +4 more sources

Efficacy of Laser Capsulotomy in the Treatment of Posterior Capsule Opacification

open access: yesJournal of Rawalpindi Medical College, 2010
Background: Neodymium – Ytrium – Aluminim – Garnet (Nd:YAG) laser capsulotomy is an effective treatment of posterior capsule opacification , but is not without its attendant risks Methods: In this interventional study, 200 Eyes with posterior capsule ...
Wajeeha Rasool
doaj   +6 more sources

Comparison of two Nd:YAG laser posterior capsulotomy: cruciate pattern vs circular pattern with vitreous strand cutting [PDF]

open access: yesInternational Journal of Ophthalmology, 2018
AIM: To investigate the effects and safety of neodymium: yttrium-aluminium-garnet (Nd:YAG) laser posterior capsulotomy with vitreous strand cutting METHODS: A total of 40 eyes of 37 patients with symptomatic posterior capsular opacity (PCO) were ...
Jin-Soo Kim   +4 more
doaj   +2 more sources

Complications after Nd YAG Posterior Capsulotomy [PDF]

open access: yesJournal of Rawalpindi Medical College, 2007
Background: To analyse the rate of complications associated with Nd YAG posterior capsulotomy. Methods: This prospective clinical study was conducted in Holy Family Hospital over a six-month period. It included five hundred and fifty patients in out door
Ali Raza
doaj   +2 more sources

Comparison of Nd:YAG Laser Posterior Capsulotomy Techniques: Cruciate Versus Circular

open access: yesMajallah-i Dānishgāh-i ̒Ulūm-i Pizishkī-i Bābul, 2016
BACKGROUND AND OBJECTIVE: Nd:YAG laser posterior capsulotomy is a standard method for treatment of posterior capsule opacification (PCO) in adults. However, there is not enough information available regarding the advantages and disadvantages of its ...
R Rezaei   +3 more
doaj   +1 more source

Effect of Neodymium: Yttrium-Aluminium-Garnet Laser Posterior capsulotomy on refractive status of the Eye [PDF]

open access: yesJournal of Rawalpindi Medical College, 2021
Objective: To assess the effect of Neodymium: Yttrium-Aluminium (Nd: YAG) laser posterior capsulotomy on the refractive status of the eye. Study Design: Quasi-experimental. Setting: Outpatient department of Benazir Bhutto Hospital, Rawalpindi.
Kanwal Zareen Abbasi   +4 more
doaj   +2 more sources

LASER POSTERIOR CAPSULOTOMY IN CASE OF THE 1ST DEGREE OF POSTERIOR CAPSULAR OPACITY OF THE LENS IN PSEUDOPHAKIC EYES [PDF]

open access: yesОфтальмохирургия, 2015
Purpose. To identify indications for laser posterior capsulotomy in case of the 1st degree of posterior capsular opacity (PCO) of the lens in pseudophakic eyes.Material and methods. The study was carried out in 43 patients (43 eyes) aged 45-74 years old,
A. D. Chuprov   +2 more
doaj   +1 more source

An unusual case of hemorrhage along the capsulotomy margin following Nd YAG capsulotomy

open access: yesJournal of Clinical Ophthalmology and Research
Posterior capsular opacification is the most common cause of reduced vision postcataract surgery. It is treated with neodymium: yttrium–aluminum–garnet capsulotomy, and patients usually have good vision following the procedure.
Thanuja Gopal Pradeep
doaj   +2 more sources

Acute Elevations of Intraocular Pressure Following Nd:YAG Laser Posterior Capsulotomy

open access: yesOphthalmology, 1985
We performed applanation tonometry preoperatively, hourly for the first four postoperative hours and on the first postoperative day in 66 eyes after Nd:YAG laser posterior capsulotomy in order to determine the nature of the acute intraocular pressure ...
Richard K Parrish, R K Parrish
exaly   +2 more sources

Home - About - Disclaimer - Privacy