Results 291 to 300 of about 6,822,454 (350)
Some of the next articles are maybe not open access.

Ampacity Estimation for Submarine Power Cables Installed in Saturated Seabed—Experimental Studies

IEEE transactions on industry applications, 2020
The maximum current carrying capacity (ampacity) of power cables depends on the heat transferability of its surrounding medium. Submarine power cable ampacity is calculated conventionally following the international standards defined for underground ...
Nishanthi Duraisamy, H. Gooi, A. Ukil
semanticscholar   +1 more source

The use of hydronic asphalt pavements as an alternative method of eliminating hot spots of underground power cables

, 2020
It is well-known that a Hydronic Asphalt Pavement (HAP) system represents an alternative method to collect heat from the Sun. In case of installation above underground power cables whose trench is completely filled with high thermal conductivity bedding,
D. Klimenta, D. Tasic, M. Jevtić
semanticscholar   +1 more source

Underground power cables

Engineering & Technology Reference, 2012
Underground cables are generally installed out of sight and are expected to operate without maintenance for at least 40 years. They are likely to represent the most valuable asset in a utility distribution network. Basic cable design has changed little over more than a century since the first cables enabled the beginning of electricity distribution in ...
openaire   +1 more source

Power cable ampacities

Electrical Engineering, 1962
The Insulated Power Cable Engineers Association published in 1943 the original edition of “Current Carrying Capacity of Impregnated-Paper, Rubber and Varnished Cambric Insulated Cables.” The excellent tables in this book were based on the best American practice at the time they were published and, as the title implies, were quite extensive in their ...
J. H. Neher   +7 more
openaire   +1 more source

The basics of power cable

Conference Record of 1993 Forty-Fifth Annual Conference of Electrical Engineering Problems in the Rubber and Plastics Industries, 1994
Insulated power cables can seem to be complicated. In fact, many cables are electrically sophisticated. To simplify we must understand the cable's components and the basics of conductor cables. These fundamentals apply to multiple conductor cables.
openaire   +1 more source

Affine Projection Algorithm-Based High-Order Error Power for Partial Discharge Denoising in Power Cables

IEEE Transactions on Instrumentation and Measurement, 2020
The onsite partial discharge (PD) detection of cable insulation is of great importance for power system maintenance. To preserve more basic features of denoised PD signal, in this paper, a PD denoising by a new class of affine projection algorithm (APA ...
Lu Lu   +5 more
semanticscholar   +1 more source

Online multi-parameter sensing and condition assessment technology for power cables: A review

Electric power systems research, 2022
Yuxuan Song   +8 more
semanticscholar   +1 more source

Real-Time Determination of Depth of Burial Profiles for Submarine Power Cables

IEEE Transactions on Power Delivery, 2019
The safe operation of submarine power cables at high load is of highest relevance for an economic and reliable operation of offshore wind farms and submarine interconnection systems. Burial of power cables at a certain minimum depth is often required for
J. Lux   +3 more
semanticscholar   +1 more source

High Temperature Superconducting Power Cables for MVDC Power Systems of Navy Ships

Electric Ship Technologies Symposium, 2019
High temperature superconducting (HTS) dc power cables need to be designed to tolerate all potential operating conditions expected on US Naval ships with medium voltage direct current (MVDC) integrated power and energy systems. These operating conditions
P. Cheetham   +7 more
semanticscholar   +1 more source

Home - About - Disclaimer - Privacy