Results 301 to 310 of about 6,822,454 (350)
Some of the next articles are maybe not open access.
2009
This chapter contains sections titled: Introduction Comparison of Overhead Lines and Cables Radial Power Systems Looped Systems Current-Carrying Capacity: Rating Equations Calculation of Losses Thermal Resistance of Cables Cyclic Loading Short-Term Overloading Fault Currents Cable System ...
openaire +1 more source
This chapter contains sections titled: Introduction Comparison of Overhead Lines and Cables Radial Power Systems Looped Systems Current-Carrying Capacity: Rating Equations Calculation of Losses Thermal Resistance of Cables Cyclic Loading Short-Term Overloading Fault Currents Cable System ...
openaire +1 more source
Physics in Technology, 1975
After a brief outline of superconductors and their behaviour in cables, the technical problems involved in the transmission of alternating current are ...
openaire +1 more source
After a brief outline of superconductors and their behaviour in cables, the technical problems involved in the transmission of alternating current are ...
openaire +1 more source
Modeling and simulation of power cable insulation
Proceedings of the International Conference and Workshop on Emerging Trends in Technology, 2010The use of power cables for transmission and distribution of electrical power have increased since the advent of suitable, reliable and economical polymeric insulating material; such as cross-linked polyethylene (XLPE). Power cables plays crucial role in the power systems, hence the failure of power cables leads to tremendous loss in terms of power ...
Kesharsing Patil +2 more
openaire +1 more source
Ice Detection on Electrical Power Cables
2015In northern countries, ice storms can cause major power disruptions such as the one that occurred on December 2013 that left more than 300,000 customers in Toronto with no electricity immediately after such an ice storm. Detection of ice formation on power cables can help on taking actions for removing the ice before a major problem occurs.
Binglin Li +2 more
openaire +1 more source
Transactions on Electrical and Electronic Materials, 2021
A. Thabet, M. Fouad
semanticscholar +1 more source
A. Thabet, M. Fouad
semanticscholar +1 more source
Rating power cables in wrapped cable trays
IEEE Transactions on Power Delivery, 1988Conductor temperatures for a given ampacity loading is a function of ambient temperature inside the tray. In other words, the ampacity of cables included in these tray systems has to be rated at the ambient temperature inside the tray. Cable overheating and eventual failure can result if cables are overloaded or not derated for operation. IPCEA Pub. No.
openaire +1 more source
OCEANS '76, 1976
Since shortly after the first submarine telegraph cable installations in the early 1800's, underwater power cables have been implanted and used. Initial acceptance and use of such cables was slow, however, and only accellerated in the past half-century with the replacement of natural rubber insulations.
openaire +1 more source
Since shortly after the first submarine telegraph cable installations in the early 1800's, underwater power cables have been implanted and used. Initial acceptance and use of such cables was slow, however, and only accellerated in the past half-century with the replacement of natural rubber insulations.
openaire +1 more source
Standardization of power cables
Journal of the Institution of Electrical Engineers - Part II: Power Engineering, 1948This paper reviews the development and present scope of British standards, published by the British Standards Institution, for insulated power cables.It is concluded that, after taking into account the wide diversity of uses for such cables, the present multiplicity of standards is not justified, and that considerable reduction of the alternative ...
openaire +1 more source
The dielectric field in an electric power cable
Proceedings of the American Institute of Electrical Engineers, 1919The data given pertain particularly to the field of three-conductor three-phase cables when supplied with three-phase voltage, and are primarily the solution by physical measurements of some of the geometric problems of the three-conductor three-phase cable.
openaire +1 more source

