Design of Hybrid Control Algorithm for Fault Ride-Through of Photovoltaic System
This paper proposes a novel control algorithm to enhance the fault ride-through (FRT) capability of a photovoltaic (PV) system. In this method, the overcurrent of the grid-tied inverter is suppressed to a preset value using model current predictive ...
Feng Zheng +5 more
doaj +1 more source
New approach to overvoltage protection of power distribution networks
U ovoj su radnji izvršene analize novih pristupa u prenaponskoj zaštiti srednjenaponskih elektroenergetskih mreža. Analizirani su nastanci i djelovanja prenapona, te je dan pregled postojećih metoda prenaponske zaštite u srednjenaponskim distribucijskim ...
Bago, Drago
core
Optimum reactive power compensation methodology to minimize system overvoltage conditions
Sri Lankan Power system has experienced power frequency over voltages at steady state conditions predominantly at New Anuradhapura, New Chilaw and Chunnakam Grid Sub Stations. New Anuradhapura being connected to the lengthiest 220kV transmission lines
Perera, CKS
core +1 more source
Wide-bandgap power devices, particularly silicon carbide (SiC) MOSFETs, have seen widespread adoption in electric vehicle (EV) motor drive systems due to their superior switching characteristics, including high switching speeds and high switching ...
Yipu Xu +4 more
doaj +1 more source
Abstract Experimental results indicate that during non-full-phase operation following a single-phase transient grounding fault, power frequency overvoltage occurs in the system. In systems with significant wind power integration, such overvoltage may lead to the disconnection of wind turbines, thereby increasing the probability of ...
Donghui Wang, Zengping Wang, Tong Wang
openaire +1 more source
Sparse modular multilevel converters (SMMCs) are a new type of lightweight high-voltage large-power AC/AC converter that significantly reduces the number of components compared to modular multilevel matrix converters (M3Cs).
Yuwei Sun +7 more
core +1 more source
Wide-bandgap transistors have short voltage rise and fall times, thus leading to overvoltage at the end of the cable connecting the inverter and the motor.
Kaspars Kroičs, Jānis Voitkāns
core +1 more source
Mechanism Analysis and Simulation Study of Closing Overvoltage Fault in EMU Circuit Breaker
Objective The overvoltage caused by circuit breaker closing will aggravate the insulation aging of high voltage equipment when EMU (electric multiple units)passes neutral section.
ZHANG Mingrui +2 more
doaj +1 more source
Over the past few years, transmission grid in the USA has seen numerous unintentional tripping events of large-scale inverter based resources (IBRs). These trippings were primarily caused by non-standard settings and certain fault ride through controls ...
Shah Mohazzem Hossain +2 more
doaj +1 more source
To enhance frequency support and fault ride-through capabilities of MMC-HVDC system, an MMC multi-time scale coordinated control strategy considering the regulation dead zone is proposed, which achieves wide-area coordinated complementarity of multiple ...
Shouqi Jiang +5 more