High-speed EMUs (electric multiple-units) frequently pass through the phase-separation zone during operation. Overvoltage generated during the operation of the vehicle-mounted circuit breaker has a long duration and high waveform steepness, which ...
Jixing Sun +5 more
doaj +2 more sources
In order to solve the problem that the long cable variable voltage and variable frequency (VVVF) system does not adopt an effective capacitor voltage sharing control method, resulting in a poor effect of resonance overvoltage control, the resonance ...
Deng Yonghong, Zhang Quanzhu
doaj +2 more sources
In the variable frequency motor drive system, because the cable impedance does not match the motor impedance, the reflection wave of the voltage wave will be generated.
Shifu Zhang +5 more
doaj +2 more sources
Overvoltage Simulation Analysis and Suppression of Breaking in a 35 kV Shunt Reactor
When a 35 kV distribution network has the problem of insufficient reactive power, the input of a shunt reactor is a common compensation method. Vacuum circuit breakers are widely used in 35 kV distribution networks because of their superior arc ...
Jing Chen +4 more
doaj +2 more sources
The Research of Voltage Sag and Power Frequency Overvoltage on 110kV Resistance Grounding System
This paper researches the voltage transfer characteristics when one-phase ground fault occurred in the resistance grounding system, by using the theory of the asymmetric variable characteristics and the sequence network analysis of the -11 transformer, and concludes the scope of voltage sag and swell and the degree of power frequency overvoltage and ...
Guo Zeng +3 more
openaire +2 more sources
Harmonic overvoltage in electric railway traction networks can pose a serious threat to the safe and stable operation of the traction power supply system (TPSS).
Qiujiang Liu +4 more
doaj +2 more sources
Study of Power Frequency Overvoltage Suppression on UHV Transmission Line
It mainly studied the improvement measures of overvoltage level for UHV transmission line from Jindongnan to Jingmen. It analyzed single-phase grounding load shedding overvoltage and fault-free load shedding overvoltage in the case of the single ...
HAN Mengmeng +3 more
doaj +2 more sources
Virtual synchronous generator (VSG) control, which can provide inertia output, damp power oscillations, and offer frequency and voltage support to power grids, has become a growing trend in the control field of wind power generation. As a new technology,
Shuyi Wang +5 more
doaj +2 more sources
When a high‐speed train approaches the insulated phase‐splitting section embedded between neighbouring power supply arms, the vacuum circuit breaker (VCB) installed on trains must be disconnected to maintain the traction power supply system as a no‐load ...
Ye Cao +13 more
doaj +2 more sources
Study on the Influence of Grounding Resistance on Cable Fault Overvoltage
The cable grounding connecting method and grounding resistance have a significant influence on the cable fault overvoltage. This paper considers a 500 kV long cable project in Beijing as the research object; a model was implemented in ATP-EMTP, and ...
Baotong Song +4 more
doaj +2 more sources