Results 71 to 80 of about 7,540 (299)
Electrical faults can change the power quality parameters of power systems. A numerical protection technique for fault detection and imbalance assessment based the Durbin-Watson (DW) factors for three phase currents is proposed in this paper.
R. A. Mahmoud
doaj +1 more source
Creep‐Induced Microstructural Evolution in an A2‐B2 Superalloy
A 27.3Ta‐27.3Mo‐27.3Ti‐8Cr‐10Al (at.%) refractory high‐entropy alloy with precipitation‐strengthened A2‐B2 microstructure was studied by creep tests at 1030°C, which demonstrate a transition in deformation mechanisms in the range of 100–150 MPa applied stress. This is associated with changes in dislocation–precipitate interactions. Relevant deformation
Liu Yang +10 more
wiley +1 more source
Power transformer protection using microcontroller-based relay [PDF]
Protection of power transformers is a very challenging problem in power system relaying. Since it is very important to minimize the frequency and duration of unwanted outages, this is a high demand imposed on power transformer protective relays.
Mariun, Norman +2 more
core +1 more source
This paper focused to determine the performance of Current Transformer (CT) operates under harmonics condition and their effects on transformer differential protection. A laboratory test has been implemented to determine the error produced by both CT and
Nisja Indra
doaj +1 more source
MODERN MICROPROCESSOR PROTECTION OF POWER TRANSFORMERS
The purpose of the present study was to understand what advantages and disadvantages in the operation of microprocessor devices in the RZA, to analyze the main series of microprocessor protection, their advantages, disadvantages and features, to review microprocessor protection in the labor market.
openaire +1 more source
The present study investigates recycling of NiTi shape memory alloys via vacuum induction melting. An ingot was synthesized from elemental Ni and Ti and subjected to three subsequent remelting cycles. Remelting increases process durations and impurity levels and adversely affects microstructures and functional properties.
Sakia Sophia Noorzayee +7 more
wiley +1 more source
Research of lightning protection gap of 35 kV power line of coal mine
In order to test lightning protection effect of protection gap for 35 kV power line, the paper simulated lightning invasion in 35 kV transformer taking 35 kV overhead line of a mine as model by use of ATP-EMPT electromagnetic transient analysis software,
DENG Jie-wen +5 more
doaj
The normal operation of the main transformer in the photovoltaic power station is the basis for the power generation output, however, the magnetizing inrush current may lead the differential protection of the transformer to malfunction.
LUAN Yunfei +4 more
doaj +1 more source
Power Transformers Differential Protection Using the p-q Power Theory [PDF]
This paper describes the application of the p-q power theory to the differential protection of power transformers. The information provided by the harmonic content of the differential active and reactive power components is used to detect winding insulation failures and to distinguish them from magnetizing inrush current transients.
Oliveira, L. M. R. +1 more
openaire +3 more sources
Current Status and Challenges in Data Collection for Aerospace Coatings Deposited by Plasma Spraying
An innovative approach has been integrated into the GRENAT project to optimize plasma spraying and coating performance. Raw materials are accelerated and melted in the plasma generated by torches, creating coatings. Monitoring sensors collect process data which are combined with ex situ characterization data.
Lila Randriamananjara +8 more
wiley +1 more source

