Results 121 to 130 of about 579,230 (391)
Reevaluating the Activity of ZIF‐8 Based FeNCs for Electrochemical Ammonia Production
Though receiving much attention, the field of electrochemical nitrogen reduction reaction (eNRR) to ammonia is marked by doubts about whether this reaction is possible in aqueous media. This work sheds light on this question for iron single‐atom on N‐doped carbon (FeNC) catalysts—a class of well‐known catalysts that is also worth testing for the sister
Caroline Schneider +6 more
wiley +1 more source
The ground fault current distribution in an effectively grounded power network is affected by various factors, such as: tower footing impedances, spans lengths, configuration and parameters of overhead ground wires and power conductors, soil ...
VINTAN, M.
doaj +1 more source
The performance of the process network in the smart substation is particularly important for relaying functions implementation, and the transmission quality of sampled value packets is becoming the key constraint on protections because they carry ...
Ruiwen He +4 more
doaj +1 more source
Fault Detection, Classification and Localization in Power Transmission Lines Using ANN
Abstract Power transmission line is key equipment in secure and reliable power flow in each power system. To arise reliability and security of overhead power lines, different types of failures should be simulated to minimize their impact and to detect and resolve them as quickly as possible. The objective of this paper is to provide an accurate
Živko Sokolović, Mileta Žarković
openaire +1 more source
Dynamic Voltage Scaling Aware Delay Fault Testing
The application of Dynamic Voltage Scaling (DVS) to reduce energy consumption may have a detrimental impact on the quality of manufacturing tests employed to detect permanent faults.
Al-Hashimi, Bashir M +3 more
core
A frequency‐tunable ferroelectric synaptic transistor based on a buried‐gate InGaZnO channel and Al2O3/HfO2 dielectric stack exhibits linear and reversible weight updates using single‐polarity pulses. By switching between ferroelectric and trap‐assisted modes depending on input frequency, the device simplifies neuromorphic circuit design and achieves ...
Ojun Kwon +8 more
wiley +1 more source
With the integration of large-scale renewable energy sources, the risk of power system operation has increased significantly. To effectively prevent large-scale blackout incidents, it is essential to identify the critical transmission lines within the ...
Gang Ruan +5 more
doaj +1 more source
MAMAWEL is introduced as the first calibration‐free potentiometric sensor for at‐home mastitis diagnosis. By measuring the sodium‐to‐potassium ratio in breast milk, the device reliably differentiates between healthy and mastitis‐affected samples with less than 10% error.
Ali Soleimani +9 more
wiley +1 more source
Protection of transmission lines using fault component integrated power
In this study, a novel scheme is proposed for pilot protection of transmission line based on the fault component integrated power (FCIP). An appropriate definition is proposed for FCIP. The proposed scheme is able to quickly discriminate the normal condition, internal fault and external fault situations, even in severe operating and emergency ...
Tohid Ghanizadeh Bolandi +2 more
openaire +1 more source
High Impedance Fault Identification in TCSC-Compensated Power Transmission Lines
Mohammed H. H. Musa